PAGE 4
TECH SHEET - DO NOT DISCARD
PART NO. 3954702 REV. A
FOR SERVICE TECHNICIAN'S USE ONLY
SPIN AND DRAIN TEST
Refer to Figure 2. This test sequence assumes the control is off. Water should be present in unit before this test is started. Note: you
may use this test or just select EXTENDED SPIN (press RINSE/SPIN OPTIONS twice) and START to use the stand-alone EXTENDED SPIN
cycle.
STEP # PRESS TOUCHPAD
DISPLAY
CONTROL ACTION
1
Key Dance:
SET DELAY TIME
⇒
END OF CYCLE SIGNAL
⇒
SET DELAY TIME
⇒
END OF CYCLE SIGNAL
DIAGNOSTIC TEST INDICATOR
The Spin and Drain Test is activated.
Key dance must be completed within 5 seconds to be valid.
2
JEANS/COLORS
Activates 60-rpm spin and drain test.
Shuts off automatically after 40 seconds.
NUTATE AND RECIRCULATE TEST
Refer to Figure 1. This test sequence assumes the control is off. The test will self-terminate after 3 minutes.
STEP # PRESS TOUCHPAD
DISPLAY
CONTROL ACTION
1
Key Dance:
SET DELAY TIME
⇒
END OF CYCLE SIGNAL
⇒
SET DELAY TIME
⇒
END OF CYCLE SIGNAL
DIAGNOSTIC TEST INDICATOR
The Nutate And Recirculate Test is activated.
Key dance must be completed within 5 seconds to be valid.
2
WASH/RINSE
TEMP
“00” on the display
3
repeat
Cold Water Inlet Valve and Fabric Softener dispenser valve on.
Cold/Cold and Normal (above WASH TIME) LEDs will turn on.
4
WASH TIME
Normal LED will turn off and Normal-Maximum LED will turn on.
Fabric softener valve will shut off and Fresh water valve will turn on.
5
WASH/RINSE
TEMP
Normal-Maximum LED will turn off and Minimum will turn on.
Fresh water valve will turn off and Detergent dispenser valve will turn on.
6
repeat
Both hot and cold inlet valves turn on.
7
none
none
Wait about 10 seconds until enough water is in tub.
8
WASH/RINSE
TEMP
All valves turn off.
9
START
LED flashes, then
constant ON
Wash plate begins nutating at 150 RPM.
10
HEAVY DUTY,
NORMAL, DELICATE,
ULTRA HANDWASH,
WOOL/SILK
LED flashes, then
constant ON
These keys can increase the nutate speed if necessary (optional).
11
CUSTOM
PROGRAM
none
Pump should turn on in recirculate mode.
Press
CUSTOM PROGRAM
again to turn off pump.
12
STOP/CANCEL
All LEDs Off
Cancel all diagnostics, go back to Off mode.
Key Dance
Press to activate Spin and Drain
Test
completing Key Dance
after
Key Dance must be completed
before proceeding with test
Figure 2: Key Dance for Spin/Drain Test