26
8-4. TROUBLESHOOTING WITH ERROR
INLET VALVE ERROR
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
When you press both
Wash Temp button and
DELAY STRAT button
simultaneously,
is the water level < 246?
Is the voltage at the inlet
valve coil 120VAC with the
valve energized?
ALWAYS CHECK FOR EXTERNAL CAUSES
Water supply shut off
Frozen water lines
Kinked fill hose
Low water pressure
Is the wiring correct? Refer to
the wiring diagram for correct
connections.
(Refer to 9-5 wiring diagram)
Is the water level still < 246?
Is filter inlet valve clogged
with foreign material?
Check the connectors at the
main PCB and the water
valve. Are the connectors
loose or disconnected?
Is the resistance of fill valve
coil between 800 and
1200
?
(Refer to 9-5 inlet valve
assembly.)
Yes
Replace the
INLET VALVE
ASSEMBLY.
Replace the
MAIN HARNESS.
Check the
pressure
switch. Refer to
test #2.
Replace the MAIN PWB
ASSEMBLY.
Reconnect or
repair
the connector.
Replace the
INLET VALVE
ASSEMBLY.
Clean or
replace the filter.
Check the AIR
CHAMBER
and the tube
(clogged).
Proceed to next step at right.
Is displayed?
Содержание 796.4107 31 Series
Страница 2: ...JULY 2012 PRINTED IN KOREA P No MFL67307945 ...
Страница 12: ...5 OPERATION 13 5 1 CONTROL PANEL FEATURES ...
Страница 13: ...14 ...
Страница 16: ...17 To use the Save Energy feature press and hold the Pre Wash button for five seconds 5 3 CYCLE OPTIONS ...
Страница 20: ...6 TROUBLESHOOTING SUMARTY 21 ...
Страница 21: ...22 ...
Страница 22: ...SPIN SPEED SOIL LEVEL WASH RINSE DELAYWASH 7 TEST MODE 23 ...
Страница 26: ...27 DRAIN ERROR Wash Temp DELAY WASH SPIN SPEED SOIL LEVEL ...
Страница 34: ... 0 1 2 3 3 4 35 ...
Страница 37: ... 9 COMPONENT TESTING INFORMATION 38 ...
Страница 44: ...45 9 5 INLET VALVE ASSEMBLY ...
Страница 46: ...47 9 7 THERMISTOR ASSEMBLY Circuit in the MAIN PCB Wiring Diagram ...
Страница 59: ...60 F300 F227 F226 F220 F432 F130 F120 F441 F430 F225 F329 F340 F327 F160 F170 F180 F321 F462 F323 F322 ...