Troubleshooting and fault elimination
Kendrion INTORQ | BA 14.0217 | 07/2021
79
10
Troubleshooting and fault elimination
If any malfunctions should occur during operations, please check for possible causes based on the follow-
ing table. If the fault cannot be fixed or eliminated by one of the listed steps, please contact customer ser-
vice.
Fault
Cause
Remedy
Brake cannot be re-
leased, air gap is not
zero
Coil interruption
¾
Measure coil resistance using a multimeter:
– Compare the measured resistance with the nominal resistance.
Refer to Rated data for coil power, Page 25 for the values.
– If resistance is too high, replace the complete spring-applied
brake.
Coil has contact to
earth or between
windings
¾
Measure coil resistance using a multimeter:
– Compare the measured resistance with the nominal resistance.
Refer to Rated data for coil power, Page 25 for the values. If re-
sistance is too low, replace the complete stator.
¾
Check the coil for short to ground using a multimeter:
– If there is a short to ground, replace the complete spring-ap-
plied brake.
¾
Check the brake voltage (refer to section on defective rectifier, volt-
age too low).
Wiring defective or
wrong
Check the wiring and correct.
¾
Check the cable for continuity using a multimeter
– Replace a defective cable.
Rectifier defective or
incorrect
¾
Measure rectifier DC voltage using a multimeter.
¾
If DC voltage is zero:
¾
Check AC rectifier voltage.
¾
If AC voltage is zero:
– Switch on power supply
– Check fuse
– Check wiring.
¾
If AC voltage is okay:
– Check rectifier,
– Replace defective rectifier
¾
Check coil for inter-turn fault or short circuit to ground.
¾
If the rectifier defect occurs again, replace the entire spring-applied
brake, even if you cannot find any fault between turns or short cir-
cuit to ground. The error may only occur on warming up.