Commissioning and operation
Kendrion INTORQ | BA 14.0217 | 07/2021
66
1. Make sure that the motor and brake are de-energized.
2. Pull (with some force) on the lever until the force increases sharply.
– The rotor must now rotate freely. A small residual torque is permissible.
NOTICE
¾
Make sure that the brake it not subject to excessive force.
¾
Do not use auxiliary tools (e.g. extension pipes) to facilitate the air release. Auxiliary
tools are not permitted and are not considered as proper and intended usage.
3. Release the lever.
– A sufficient torque must build up immediately!
Notice
If faults occur, refer to the error search table (Troubleshooting and fault elimina-
tion, Page 79). If the fault cannot be fixed or eliminated, please contact the customer service
department.
8.3
Commissioning
DANGER
Danger: rotating parts!
¾
The brake must be free of residual torque.
¾
The drive must not be running when checking the brake.
DANGER
There is a risk of injury by electrical shock!
The live connections must not be touched.
1. Switch on your drive system.
2. Perform a test braking procedure; if necessary, reduce the braking torque (depending on your specifi-
cations and requirements)