Technical specifications
Kendrion INTORQ | BA 14.0217 | 07/2021
31
The following table specifies the permissible friction work [J], depending on the number of switching opera-
tions, that is typical for facility acceptance tests (This information differs from the values given in the oper-
ating instructions for the standard spring-applied brake BFK458!)
Notice
The number of switching operations must be evenly distributed over the course of one hour.
Size
Number of switching operations per hour
Permissible friction work
[J]
06
6
2500
10
2498
08
6
6798
10
6754
10
6
10986
10
10799
12
6
21329
10
20317
14
6
28727
10
27237
16
6
34117
10
32181
18
6
48216
10
43233
20
6
73755
10
65483
25
6
110150
10
93224
Tab. 10:
Permissible friction work [J], depending on the number of switching operations that is typical for facility
acceptance tests