19
EN
Operating instructions CellaTemp PK / PKF / PKL xx
11 Setup
The pyrometer uses the intensity of infrared radiation for non-contact temperature
measurements� It is necessary to configure the pyrometer to the respective
emissivity coefficient of the measuring object to obtain exact measuring results (→
15 Emissivity coefficient tables)� An incorrectly set emissivity coefficient leads to
wrong temperature readings�
Set the emissivity coefficient after connecting the supply voltage or resetting the
parameters to factory settings�
►
Press [
▲or ▼]
> the value of the selected emissivity is displayed, for example [
100.0
]
►
Press [
▲or ▼] until the desired emissivity is shown
►
Press [Enter] or wait for 3 seconds
The current temperature value is displayed� The pyrometer now works with this
configured emissivity until it is changed again�