Operating instructions CellaTemp PK / PKF / PKL xx
10 Menu explanation
10.1 Digital output OUT1
Parameter Function
Comments
do.SP
OUT1 Upper threshold
Upper threshold which activates OUT1
do.rP
OUT1 Lower threshold
Lower threshold which activates OUT1
doF.n
Output function
no
normally opened
nc
normally closed
do.dS
Upper threshold delay
Value in sec
(≤ 10 sec in steps of 0.1 sec)
do.dr
Lower threshold delay
Value in sec
(≤ 10 sec in steps of 0,1 sec)
End
End
10.2 Analogue output OUT2
Parameter Function
Comments
Ao. _
OUT2
Beginning of range
Analogue start value
for the range of OUT2
Ao. ~
OUT 2
End of range
Analogue end value
for the range of OUT2
Ao.04
Analogue output
0/ 4 - 20 mA
0 - 20 mA Scaling Analoque output
4 - 20 mA Scaling Analoque output
End
End