kelda 91017100 Скачать руководство пользователя страница 18

Warning!

•  The Control Hub should not be installed in an outdoor environment,
  including sheltered areas, 
•  When the control box module is installed, the mains socket must be within easy reach
•  Do not use extensions or multiple sockets
•  The power supply cable must never be bent or dangerously compressed
•  Only the supplied power supply should be used with the product.

Customer Care

Guarantee

Kelda Showers guarantees this product against any 
defect in materials or workmanship for the period of two 
years from the date of purchase. To be covered by this 
guarantee, service work must only be undertaken by 
Kelda Showers or by its approved agents.

Not Covered by this Guarantee

Damage or defects arising from incorrect installation, 
improper use or failure to maintain in accordance with the 
instructions in this product manual, including the build-up 
of limescale. Defects or damage if the product is taken 
apart, repaired or modified by a person not authorised by 
Kelda Showers or by their approved agents.

After-Sales Service

Our fully trained staff are ready to provide assistance, 
should you experience any difficulty operating your 
Kelda Showers equipment.

       

 

Spare Parts

All functional parts of Kelda Showers products are 
available. 
All spares are guaranteed for 12 months from date of 
purchase. 
Spares that have been supplied directly from us can be 
returned within one month from date of purchase, 
providing that they are in good order and the packaging is 
unopened. 
Note: returned spares will be subject to a 15% restocking 
charge and authorisation must be obtained from Kelda 
Showers before return.

Customer Care Policy

If within a short space of time of installation the product 
does not function correctly, first check with the operation 
and maintenance advice provided in this installation 
guide to see if the difficulty can be overcome. Failing this, 
contact your installer to make sure that the product has 
been installed and commissioned in full accord with our 
detailed installation instructions. If this does not resolve 
the difficulty, please contact Kelda Showers, who will give 
you every assistance.

!

Patents:

Patents granted and pending:

2454228

9173809

2675568

ZL201280009000.7

4146403

1692638PP/CN

1692638PP/US

1692638P/HK

1875355D/GB

1875355D/CTM

4135905

1714634P/HK

1714634PP/CN

1714634PP/US

2612790

1850858P/PCT

18

Содержание 91017100

Страница 1: ...t manual is the property of the customer and must be retained for maintenance and operational purposes SKU 91017100 shown on front cover Installation Manual and User Guide Flex Head Rear Void TMV2 The...

Страница 2: ...digit of the product code will designate the flow regulator pre fitted for example 91017104 Flex Head Rear Void Shower 4 l m 91017105 Flex Head Rear Void Shower 5 l m 91017106 Flex Head Rear Void Show...

Страница 3: ...to clear debris from before connecting to water inlets on shower 3 DO NOT solder pipes or fittings within 300mm of the supplied hoses as heat can transfer along the pipework and damage components 4 D...

Страница 4: ...scription Fan speed UP DWN Timer settings UP DWN Backplate Casing Air Inlet 24V Power Supply Cable Blower Power In Terminal Main PCB Air Outlet Flow Sensor Cable Front Cover Four Lid Clips Control Hub...

Страница 5: ...flow sensor Flex Shower head 12 Nozzle 1 Control Hub P23 2 Flow sensor Flex Head 91017100 Air inlet hose length 100mm if re circulation is not chosen 100 240V Mains electricity supply via the OWA 60W...

Страница 6: ...ead Flow sensor assembly x1 Fixing Kit x2 Fixing back nuts x4 Screws x4 Wall plugs x1 Pipe spacer x1 Air supply hose x1 Air inlet hose x4 Jubilee Clips x1 90 degree elbow 19mm x1 3 4 Inch Air nut Spec...

Страница 7: ...switch must be within easy reach Do not use extensions or multiple sockets The power supply cable must never be bent or dangerously compressed Only use the supplied power supply Two people are require...

Страница 8: ...er the Control Hub with its lid and secure the fastening clips Drill the holes for the screws to go into the wall Screw them into place with the Control Hub mounted on the wall using a screwdriver 3 4...

Страница 9: ...nto the void wall and secure using the screws supplied Make sure the spacer is centered by using the viewing windows in the spacer Remember Read through all instructions before beginning installation...

Страница 10: ...Ensure hose connections are airtight This can be done when first running the shower Use the elbow connector and jubilee clip to connect the air outlet hose to the shower head backplate If air recircul...

Страница 11: ...with Part P U K Building Regulations and to the latest IEEE standards or the appropriate regulations in the country of installation 32A 30mA RCBO Up to 12 Showers 3A Switched Fused Spur AC 100 240V to...

Страница 12: ...o change the fan speed settings press FAN button once There are 6 speed settings 1 6 3 To display current fan speed set press and hold FAN button for 2 seconds The number of LED flashes corresponds to...

Страница 13: ...ale Fan Overheat Protection Fan Test Function Press and hold TMR button for more than 5 seconds to run the fan independently of full shower operation In the unlikely event of the fan overheating from...

Страница 14: ...service strainers and cartridge see mixer instructions to service Pressure difference between hot and cold supplies is too high Adjust screws on mixer to balance Or fit pressure reducer on high pressu...

Страница 15: ...ons for dismantling and reassembling head for cleaning If showers are in a high usage area or where the water feed to showers has high hardness levels this will be required more frequently Bi Annual V...

Страница 16: ...t solution and flush through continue this until hoses are clean Once hoses are clean flush hoses through with fresh water Shake out any excess water and wipe dry Replace air supply hose by gently ins...

Страница 17: ...t cover 2 60010 79054 79076 79108 79110 P23 Control Hub replacement complete unit PCB Fan Duct Backplate Casing Lid Clips 3 35017 19mm 1000mm Air hose 19mm 1000mm Air Hose 4 32008 32009 TMV2 Mixer Val...

Страница 18: ...de assistance should you experience any difficulty operating your Kelda Showers equipment Spare Parts All functional parts of Kelda Showers products are available All spares are guaranteed for 12 mont...

Страница 19: ...DISPOSAL Do not dispose of with household waste Please recycle where facilities exist Check with your local authority for recycling advice Installation Template Flex Fixed AV Shower head 91017100 9101...

Отзывы: