Kelda Showers products are precision-engineered and should give continued superior and safe performance, provided:
1.
They are installed, commissioned, operated and maintained in accordance with this installation guide.
2.
Periodic attention is given as necessary to maintain the product in good functional order.
Guidelines for frequency are given below. Maintenance must be carried out in accordance with these instructions, and
must be conducted by designated, qualified and competent personnel. Components are precision-made, so care must
be taken during maintenance to avoid damage.
Daily/Weekly Hygiene
External surfaces of the shower head may be wiped clean with a soft cloth and if necessary, a mild detergent or soap
solution can be used.
Quarterly Hygiene*
Shower heads to be dismantled to clean, de-scale and sanitise removable parts, heads and inserts.
Please see instructions for dismantling and reassembling head for cleaning.
*If showers are in a high usage area or where the water feed to showers has high hardness levels this will be required
more frequently.
Bi-Annual Visual & Hygiene
Check internal component condition of the shower head and hoses. Inspect for debris, scale deposition, deformation,
damage, etc. Maintain or renew if necessary. Please see Instructions for cleaning and disinfection of air hose and Control
Hub
Maintenance
1.
Remove the fascia plate screw cap with a small flat head screwdriver (1)
2.
Remove centre screw using a pozidriv PZ2 ensuring the fascia plate (2) and atomisation engine (3) are held until
screw removed.
3.
Slowly lower fascia plate and atomisation engine.
4.
Carefully detach the rubber hose from the water chamber (4) ensuring not to remove the hose from the other end.
5.
Carry out clean, de-scale and sanitisation of shower head components in line with our maintenance guidelines.
6.
To reassemble, follow steps in reverse.
Instructions for Dismantling and Reassembling Head for
Cleaning
2.
3.
4.
5.
Flex Head
81003100
15