kelda 91017100 Скачать руководство пользователя страница 1

This shower must be used with compatible TMV2 shower mixer/valve or timed flow control valve

Rear Access Void Shower

Important:

This product manual is the property of the customer and must be retained for maintenance and operational purposes.

SKU 91017100 shown on front cover.

Installation Manual and 

User Guide

Flex Head - Rear Void TMV2 Thermostatic  

 

        

91017100

Flex Head - Rear Void TMV2 Thermostatic 

 

 

91020100

Flex Head - Rear Void TMV2 Thermostatic 

 

 

91021100

Nov 2023

Part No. 24017

1

Содержание 91017100

Страница 1: ...t manual is the property of the customer and must be retained for maintenance and operational purposes SKU 91017100 shown on front cover Installation Manual and User Guide Flex Head Rear Void TMV2 The...

Страница 2: ...digit of the product code will designate the flow regulator pre fitted for example 91017104 Flex Head Rear Void Shower 4 l m 91017105 Flex Head Rear Void Shower 5 l m 91017106 Flex Head Rear Void Show...

Страница 3: ...to clear debris from before connecting to water inlets on shower 3 DO NOT solder pipes or fittings within 300mm of the supplied hoses as heat can transfer along the pipework and damage components 4 D...

Страница 4: ...scription Fan speed UP DWN Timer settings UP DWN Backplate Casing Air Inlet 24V Power Supply Cable Blower Power In Terminal Main PCB Air Outlet Flow Sensor Cable Front Cover Four Lid Clips Control Hub...

Страница 5: ...flow sensor Flex Shower head 12 Nozzle 1 Control Hub P23 2 Flow sensor Flex Head 91017100 Air inlet hose length 100mm if re circulation is not chosen 100 240V Mains electricity supply via the OWA 60W...

Страница 6: ...ead Flow sensor assembly x1 Fixing Kit x2 Fixing back nuts x4 Screws x4 Wall plugs x1 Pipe spacer x1 Air supply hose x1 Air inlet hose x4 Jubilee Clips x1 90 degree elbow 19mm x1 3 4 Inch Air nut Spec...

Страница 7: ...switch must be within easy reach Do not use extensions or multiple sockets The power supply cable must never be bent or dangerously compressed Only use the supplied power supply Two people are require...

Страница 8: ...er the Control Hub with its lid and secure the fastening clips Drill the holes for the screws to go into the wall Screw them into place with the Control Hub mounted on the wall using a screwdriver 3 4...

Страница 9: ...nto the void wall and secure using the screws supplied Make sure the spacer is centered by using the viewing windows in the spacer Remember Read through all instructions before beginning installation...

Страница 10: ...Ensure hose connections are airtight This can be done when first running the shower Use the elbow connector and jubilee clip to connect the air outlet hose to the shower head backplate If air recircul...

Страница 11: ...with Part P U K Building Regulations and to the latest IEEE standards or the appropriate regulations in the country of installation 32A 30mA RCBO Up to 12 Showers 3A Switched Fused Spur AC 100 240V to...

Страница 12: ...o change the fan speed settings press FAN button once There are 6 speed settings 1 6 3 To display current fan speed set press and hold FAN button for 2 seconds The number of LED flashes corresponds to...

Страница 13: ...ale Fan Overheat Protection Fan Test Function Press and hold TMR button for more than 5 seconds to run the fan independently of full shower operation In the unlikely event of the fan overheating from...

Страница 14: ...service strainers and cartridge see mixer instructions to service Pressure difference between hot and cold supplies is too high Adjust screws on mixer to balance Or fit pressure reducer on high pressu...

Страница 15: ...ons for dismantling and reassembling head for cleaning If showers are in a high usage area or where the water feed to showers has high hardness levels this will be required more frequently Bi Annual V...

Страница 16: ...t solution and flush through continue this until hoses are clean Once hoses are clean flush hoses through with fresh water Shake out any excess water and wipe dry Replace air supply hose by gently ins...

Страница 17: ...t cover 2 60010 79054 79076 79108 79110 P23 Control Hub replacement complete unit PCB Fan Duct Backplate Casing Lid Clips 3 35017 19mm 1000mm Air hose 19mm 1000mm Air Hose 4 32008 32009 TMV2 Mixer Val...

Страница 18: ...de assistance should you experience any difficulty operating your Kelda Showers equipment Spare Parts All functional parts of Kelda Showers products are available All spares are guaranteed for 12 mont...

Страница 19: ...DISPOSAL Do not dispose of with household waste Please recycle where facilities exist Check with your local authority for recycling advice Installation Template Flex Fixed AV Shower head 91017100 9101...

Отзывы: