05
INSTALLATION INSTRUCTIONS
TRIPLE TRAINER
• Keiser Professional Installation Service.
A trained technician from Keiser’s installation network will perform the
installation.
• Choose Your Own Professional Installation Service.
Keiser Installation Instructions provide detailed instructions
on how to install the equipment into solid concrete, along with information on the proper tools and anchors required.
CONCRETE AND FLOORING
•
Equipment installation must be on solid, level concrete surface, minimum 5” (127 mm) thick.
• Minimum concrete compressive strength: 3,000psi (20.7 MPa).
• New concrete must be fully cured before equipment installation.
•
Flooring (i.e. rubber/carpet/artificial turf, including underlayment) over
5/8” (16 mm)
thick will require an appropriate
anchor length (refer to the Anchor Selection Guide below).
SECURING THE TRIPLE TRAINER
MOUNTING REQUIREMENTS
INSTALLATION OPTIONS
ANCHORING
• Equipment must be installed with the Floor Mount Plate.
• Use all four anchor holes on the Floor Mount Plate to secure the equipment.
• Follow all safety and installation instructions of the anchor and adhesive manufacturers.
• Do not reuse anchors. Anchors are designed for one-time use only.
• Adhesive application required (supplied).
Professional installation required. It is the responsibility of the facility owner to adhere to local and regional building codes.
ANCHOR SELECTION GUIDE
No Flooring
(concrete)
Flooring
up to 5/8” (16 mm) thick
Flooring
over 5/8” (16 mm) thick
3/8” x 4”
Concrete Screw Anchors
(supplied)
Embedment depth: 3-5/8” (92 mm)
3/8” x 4”
Concrete Screw Anchors
and Spacers (supplied)
Embedment depth: 3” (76 mm)
3/8” dia. anchor with appropriate
length (not supplied)
and Spacers (supplied)
Min. embedment required: 3” (76 mm)
Factor in 3/8” (9.5 mm) Floor Mount
Plate and flooring thickness when
selecting the appropriate screw
anchor.
•
Anchors must have minimum embedment depth in concrete as specified by the manufacturer.
•
Minimum hole depth overdrill: 1/2” (13 mm).