AIR SYSTEM SETUP & FINAL INSTALLATION 

REFER TO THE DIAGRAM ABOVE FOR AIR SYSTEM SETUP AND FOLLOW THE INSTRUCTIONS BELOW

1. 

TOOLS: Cutters, Adjustable Wrench, and 3/16 in. Allen Wrench. Remove the Male Luers from each Functional Trainer and 
install Quick Disconnects (quantity 3, included in kit) to connect to the Air Manifold. Air Manifold Configurations: 1/4 in. 

air line (as shown) or 3/8 in. for direct connection to the Compressor. NOTE: Reverse Plug and Connector positions to 

accommodate subfloor air supply.

WARNING: Never connect Keiser pneumatic equipment to an air source that is capable of exceeding 120 psi / 8.27 bar.

 

Over pressurizing Keiser pneumatic equipment may cause tubing to burst, breakage of equipment, abnormal operation, or 
serious injury. Use only clean, dry, regulated compressed air at the rated pressure range of 100–120 psi / 6.89–8.27 bar.

2.  Connect the Air Tube from the Air Manifold outlet into the Compressor (Compressor not included, sold separately). Ensure 

the Quick Disconnect clicks into position. 

3.  Plug the Compressor into a power source to power the Compressor ON. Allow the Compressor to build up to a minimum 

of 100 psi / 6.89 bar.

POWER ON THE EQUIPMENT

Press the “+” and then the “-” Thumb Buttons a few times 
on each Functional Trainer to ensure air cycles through 
and that the Power Display powers ON.
NOTE: Keiser Air Compressor manuals are available for 
viewing and download at 

keiser.com/support

 (search: Air 

Compressor manuals).

Apply 
Loctite

®

 242 

to threads

Connect to 

Compressor Outlet

Plug

Air Manifold

Compressor

Tube Insert

Air Tube with QD

Install

x3 Quick Disconnect

(QD)

Remove

x3 Male Luer

Thumb 

Buttons

Power Display

Powered ON

1. 

Make sure the Triple Trainer has been installed according 

to the instructions.

2.  Ensure that the Triple Trainer is connected to the 

Compressor/Air Supply and that the Compressor/Air 
Supply is powered ON.

3.  Read the Operation Manual, enclosed with the equipment 

and available at 

keiser.com/support

 (search: Functional 

Trainer Manual).

4.  Store Installation Instructions for future reference.

BEFORE YOU USE THE TRIPLE TRAINER

WARNING: Avoid potential injury and/or property 

damage. 

Ensure the Floor Mount Plate is securely fastened 

to the concrete floor. If movement is found, check all 

Screw Anchors and Mount Screws and ensure that they 

are all firmly fastened before use.

1/4 in. 

Connector

Содержание INFINITY 3020XA

Страница 1: ...or operation of the Triple Trainer after reading this manual contact Keiser Customer Support 1 559 256 8000 service keiser com keiser com support Telephone and Live Chat Monday Friday 9 am to 5 pm PS...

Страница 2: ...LS AND MATERIALS 06_UNPACKING 07_PARTS LIST 08_STEP BY STEP INSTALLATION GUIDE 11_AIR SYSTEM SETUP FINAL INSTALLATION 11 BEFORE YOU USE THE TRIPLE TRAINER This equipment contains electrical or electro...

Страница 3: ...ive equipment PPE observe all governing codes and ordinances 12 Safety Glasses required during installation 13 Use a dust collection system when drilling clean area using a HEPA vacuum Avoid breathing...

Страница 4: ...Length may vary based on Accessory type user height and the position setting of the exercise Arm To safely and effectively use your Training Space remember to 1 Clear your Training Space Ensure there...

Страница 5: ...TION OPTIONS ANCHORING Equipment must be installed with the Floor Mount Plate Use all four anchor holes on the Floor Mount Plate to secure the equipment Follow all safety and installation instructions...

Страница 6: ...area has been planned according to the training space required refer to the Training Space section page 4 UNPACKING Figure 3 Unpacking the Triple Trainer Safety Glasses High Quality Floor Wall Scanne...

Страница 7: ...8Cx1 8M in 8078 11 3 Male Quick disconnect QD 110897 12 1 Air Tube with Luer and Quick Disconnect 953108 8086 110897 13 12 Washer 3 8 in 9355 14 12 Screw 3 8 16x3 4 in 9200 15 6 Screw 1 4 20x3 8 in 9...

Страница 8: ...installation is similar DRILL USING THE FLOOR MOUNT PLATE AS THE DRILL PATTERN QUANTITY 3 DRILL HOLES IMPORTANT Check the Floor Mount Plate alignment as each hole is drilled to avoid costly rework CO...

Страница 9: ...Anchor through the Floor Mount Plate and into the drill holes Tighten the Screw Anchors into the concrete until the hex washer head contacts the surface of the Floor Mount Plate Immediately remove an...

Страница 10: ...for the remaining two Brackets B A 7 Remove x2 1 4 20x1 4 in Phillips Screws BRACKET INSTALLATION PREPARATION Remove the top two 1 4 20x1 4 inch Phillips Screws along the sides of the Functional Train...

Страница 11: ...the Compressor into a power source to power the Compressor ON Allow the Compressor to build up to a minimum of 100 psi 6 89 bar POWER ON THE EQUIPMENT Press the and then the Thumb Buttons a few times...

Страница 12: ...uestions regarding the installation or operation of the Triple Trainer after reading this manual contact Keiser Customer Support 305522_B 1 559 256 8000 service keiser com keiser com support Telephone...

Отзывы: