AIR300 LEG PRESS OPERATION MANUAL

LINE 1 - RESISTANCE

The Resistance window displays the current resistance or OFF. Adjust the resistance using the (+/-) Thumb Buttons located 

on either side of the Seat. When the window displays OFF, the machine enters a low power consumption sleep mode to 
increase battery life. Normal operation may be resumed by pressing either Thumb Button or by inserting the eChip. If this 
window displays t

he low battery signal (“Lo-bA”)

, the batteries are getting weak and should be replaced soon (D batteries, 

quantity 2; refer to page 16 “Battery Replacement” for complete instructions).

LINE 2 - SET OR REPETITIONS

This window displays the current repetition count except immediately after an eChip is first inserted, in which case it displays 

the current set. The set count may range from 1 to 9 and is signaled by the appearance of three horizontal bars in the left 

digit. The number of sets is defined as the number of sets of exercises performed in a four-hour period. Once four hours have 

passed, the machine assumes that the user is returning for a new visit. The repetition count may range from 0 to 99. The 

repetition count may be reset by momentarily pressing both increase and decrease (+/-)Thumb Buttons simultaneously. In 

Power Test mode, the window will display the repetition count per test section (refer to page 14 “Power Test” for complete 

instructions).

LINE 3- TARGET REPS

The Target Reps window displays the number of repetitions performed on the corresponding set of the previous visit, if that 
set was a normal workout set and an eChip is inserted. If the corresponding set of the previous visit was a Power Test, the 
display will show “Pr.” When in Power Test mode, the window will display “P1” during the low resistance test set and “P2” 

during the high resistance test set (refer to page 14 “Power Test” for complete instructions).

LINE 4 - CURRENT POWER / PERCENT OF PEAK POWER

The Current Power window can display 4 different values. During an exercise set, it displays the percent of peak power 
achieved for the most recent repetition. At the end of a Power Test, this window displays the resistance to use to achieve 
maximum power. When an eChip is inserted and the previous corresponding set was a normal workout set, it displays the 
resistance used for that set. When an eChip is inserted, and the previous corresponding set was a Power Test, it displays the 
resistance to use to achieve maximum power. When the calculated resistance to achieve maximum power is being displayed, 

it flashes. In summary, during an exercise set, this window displays the power for the current rep, at the end of a Power 

Test it is the resistance to use for training at maximum power; when an eChip is inserted it is the resistance to set into the 
window above before exercising.

LINE 5 - PEAK POWER

The Peak Power window displays the highest power that has occurred during this workout or since the data was last reset.

LINE 6 - MACHINE ADJUSTMENT

When using the eChip, Seat position and Leg setting of the Air300 Leg Press can be tracked and recorded. Adjust by pressing 
the arrows located directly above/below each window.

SEAT POSITION

: Input your Seat Position (1 – 9, 0, A, or C) in the Seat window.

LEG SETTING

: Input “1” for exercising each leg independently or “2” for exercising both legs together in the Leg window.

NOTE: The adjustments may only be changed immediately after the eChip is inserted and before the third repetition has 
occurred. Once three repetitions are performed, the machine adjustments cannot be changed until the eChip has been 
removed and reinserted. Machine adjustments apply to a machine and cannot be changed from set to set.

LINE 7 - eCHIP READER

The eChip Reader, located at the bottom right of the Power Display, receives and reads your eChip data. 

LINE 8 - eCHIP

The eChip collects workout data and can store up to 24 separate equipment models (up to 4 equipment position settings per 

model) and up to 240 separate workout sets across Keiser Air and Infinity Series. Designed as an electronic replacement for 

the hand-written exercise card, the eChip enables recall and set-up of the exercise equipment upon the next workout. The 

Keiser eChip software allows saved eChip data to be viewed, stored, and exported (.csv file format) for analysis.
NOTE: Three user eChips (red color) come standard with your Air300 Leg Press. The Keiser USB Power Kit (a USB adapter to 
transfer data from your eChip to your computer and Time Set eChips to set the time zone/time on your Air300 Leg Press) is 

available. For parts order, contact Keiser Customer Support 

(see back cover for contact information).

Keiser eChip software system requirements, download, and user manual available at keiser.com/support

 (search: eChip).

DISPLAY FEATURES

Содержание AIR300 2531 Series

Страница 1: ...LEG PRESS MODEL 2531XX OPERATION MANUAL AIR300 STRENGTH CARDIO FUNCTIONAL...

Страница 2: ...NCE NOTICES 18_SAFETY NOTIFICATIONS 19_ELECTROMAGNETIC COMPATIBILITY EMC 19_US FCC COMPLIANCE STATEMENT 19_DISPOSAL 20 WARRANTY STATEMENT Keiser the Keiser logo and other trademarks associated with Ke...

Страница 3: ...FORMATION INTRODUCTION Register your Air300 Leg Press to stay informed of safety notifications and for faster more accurate warranty service Scan the QR Code to the right to access the interactive onl...

Страница 4: ...l toward the user and could result in serious injury or property damage Extend the Foot Pads and engage the Movable Stops to safely exit the equipment If at any time you are not able to extend your le...

Страница 5: ...ed could result in minor or moderate injury IMPORTANT Indicates information considered critical but not hazard related IMPORTANT SAFETY INFORMATION CONTINUED Maintain and do not remove safety or notif...

Страница 6: ...FICATIONS TECHNICAL DATA AIR STORAGE TANKS The equipment contains two air storage tanks air accumulator with the following operating parameters POWER 1 5V D Alkaline Batteries quantity 2 Keiser PN 966...

Страница 7: ...p to a minimum of 100 psi 6 89 bar Keiser Compressor and Keiser Air System not included sold separately 2 Connect the 1 4 inch Quick Disconnect QD from the equipment to an Outlet in the Keiser Air Sys...

Страница 8: ...hip Instruction Placards not shown 18 19 Exercise Arms 3 Air Tubes and Communication Wires 14 Seat Track and Position Settings 15 Air Tanks 7 Lock Bar 4 Increase Decrease Thumb Buttons 16 11 10 Stop R...

Страница 9: ...monitoring systems may be inaccurate Over exercising may result in serious injury or death If you feel faint stop exercising immediately Peak Power not suitable for use in applications where the healt...

Страница 10: ...nce used for that set When an eChip is inserted and the previous corresponding set was a Power Test it displays the resistance to use to achieve maximum power When the calculated resistance to achieve...

Страница 11: ...Upholstery no excessive wear free of rips or tears C Thumb Buttons and Display press Thumb Buttons to check for proper operation power on the Display D Seat Seat Lever allows the Seat to slide freely...

Страница 12: ...Movable Stops are set below the dots 1 2 3 4 5 BEFORE ENTERING THE MACHINE Set the Lock Bar to exercise one leg at a time or both together Lift the Seat Lever to adjust the Seat and comfortably enter...

Страница 13: ...old the Stop Release Bars on both sides Extend the legs fully and at the same level without locking the knees keep a slight bend in the knees Maintain erect position on the Seat and Seat Back ECCENTRI...

Страница 14: ...ing guidelines START TEST Press and hold both Thumb Buttons until 6 r Test Mode displays in the RESISTANCE window then release the Thumb Buttons NOTE TARGET REPS window displays P1 Power Test Set 1 SE...

Страница 15: ...tions NOTE Your Keiser Air Compressor not included with your Air300 Leg Press requires basic annual maintenance Contact Keiser Customer Support for Air Compressor operator manual or download at keiser...

Страница 16: ...Box Pull and remove the cover 2 Remove the 2 D batteries by carefully pulling outtheBatterySleeve followmanufacturer s recommendations for handling maintaining and disposing of batteries 3 Observe th...

Страница 17: ...ubricate Cylinder Rods Wipe the Cylinder Rods clean and coat lightly with clean SAE 30 motor oil or with a silicon based spray 5 Replace the Mufflers one on each Cylinder if discoloration is present T...

Страница 18: ...with the disposal of waste products residues including disposal of the equipment itself at the end of its useful life The Air300 Leg Press contains electronic circuit assemblies 2 alkaline D cell batt...

Страница 19: ...ECTROMAGNETIC COMPATIBILITY EMC DISPOSAL This equipment contains electrical or electronic components alkaline batteries and a sealed lithium coin cell battery that must be disposed of properly to comp...

Страница 20: ...y If you have any questions about your warranty please contact Keiser Customer Support at 1 559 256 8000 and via live chat at keiser com support Monday Friday 9 am to 5 pm Pacific Time or by email at...

Отзывы: