AIR300 LEG PRESS OPERATION MANUAL

SAFETY NOTIFICATIONS

TYPE/DEGREE OF PROTECTION

CLASSIFICATION/IDENTIFICATION/WARNINGS

SYMBOL

The degree of protection against 
electric shock

Device is powered by two D cell alkaline batteries. 
Electrical safety evaluation conducted by TÜV SÜD per
IEC/EN 60601-1 requirement.

The degree of protection against the 
ingress of liquids

Not protected

N/A

The degree of safety in the presence of 

a flammable anesthetic mixture with air 

or with oxygen or nitrous oxide

Not suitable

N/A

The mode of operation

Continuous

N/A

Information regarding potential 
electromagnetic or other interference 
and advice regarding avoidance

The Air300 Leg Press use electromagnetic and RF energy 
only for its internal function. Therefore, its EMC and RF 
emissions are very low and are not likely to cause any 
interference in nearby electronic equipment.

N/A

EMC Notices, Statement of Compliance

See 

Electromagnetic Compatibility (EMC)

 section, page 19.

N/A

ID of specified optional external power 

supplies or battery chargers

The Air300 Leg Press does not require an external power 
supply.

N/A

ID of any risks associated with the 
disposal of waste products, residues, 
including disposal of the equipment 
itself at the end of its useful life.

The Air300 Leg Press contains electronic circuit 
assemblies, 2 alkaline D cell batteries, and a sealed lithium 
coin cell battery that may require compliance with 

specific local disposal or recycling procedures.

The specification of the environmental 

conditions of transport and storage

Use indoor in climate-controlled environment only.
Keep away from areas of extreme humidity.
NOTICE: Equipment not tested at extreme high/low 
temperatures.

N/A

REGULATORY AND COMPLIANCE NOTICES

Standards

ISO/EN 20957-1 Accuracy Class A (High accuracy) and Usage Class S (Studio, 
commercial use); IEC/

EN 60601-1 and IEC/EN 60601-1-2.

Marks

Displayed watts testing parameters: 

“Current Power,” “Peak Power,” and “Percent of Peak Power” are not suitable 

for use in applications where the health and safety of a patient may be dependent on the accuracy of those parameters. 

Clinical Settings Note:

 In clinical settings, patients may operate this equipment in accordance with this user manual 

and the instructions and guidance provided by the healthcare personnel responsible for supervising their treatment 
and care. However, patients shall not perform preventive maintenance, repairs or replace batteries on equipment 
installed in clinical facilities. 

Содержание AIR300 2531 Series

Страница 1: ...LEG PRESS MODEL 2531XX OPERATION MANUAL AIR300 STRENGTH CARDIO FUNCTIONAL...

Страница 2: ...NCE NOTICES 18_SAFETY NOTIFICATIONS 19_ELECTROMAGNETIC COMPATIBILITY EMC 19_US FCC COMPLIANCE STATEMENT 19_DISPOSAL 20 WARRANTY STATEMENT Keiser the Keiser logo and other trademarks associated with Ke...

Страница 3: ...FORMATION INTRODUCTION Register your Air300 Leg Press to stay informed of safety notifications and for faster more accurate warranty service Scan the QR Code to the right to access the interactive onl...

Страница 4: ...l toward the user and could result in serious injury or property damage Extend the Foot Pads and engage the Movable Stops to safely exit the equipment If at any time you are not able to extend your le...

Страница 5: ...ed could result in minor or moderate injury IMPORTANT Indicates information considered critical but not hazard related IMPORTANT SAFETY INFORMATION CONTINUED Maintain and do not remove safety or notif...

Страница 6: ...FICATIONS TECHNICAL DATA AIR STORAGE TANKS The equipment contains two air storage tanks air accumulator with the following operating parameters POWER 1 5V D Alkaline Batteries quantity 2 Keiser PN 966...

Страница 7: ...p to a minimum of 100 psi 6 89 bar Keiser Compressor and Keiser Air System not included sold separately 2 Connect the 1 4 inch Quick Disconnect QD from the equipment to an Outlet in the Keiser Air Sys...

Страница 8: ...hip Instruction Placards not shown 18 19 Exercise Arms 3 Air Tubes and Communication Wires 14 Seat Track and Position Settings 15 Air Tanks 7 Lock Bar 4 Increase Decrease Thumb Buttons 16 11 10 Stop R...

Страница 9: ...monitoring systems may be inaccurate Over exercising may result in serious injury or death If you feel faint stop exercising immediately Peak Power not suitable for use in applications where the healt...

Страница 10: ...nce used for that set When an eChip is inserted and the previous corresponding set was a Power Test it displays the resistance to use to achieve maximum power When the calculated resistance to achieve...

Страница 11: ...Upholstery no excessive wear free of rips or tears C Thumb Buttons and Display press Thumb Buttons to check for proper operation power on the Display D Seat Seat Lever allows the Seat to slide freely...

Страница 12: ...Movable Stops are set below the dots 1 2 3 4 5 BEFORE ENTERING THE MACHINE Set the Lock Bar to exercise one leg at a time or both together Lift the Seat Lever to adjust the Seat and comfortably enter...

Страница 13: ...old the Stop Release Bars on both sides Extend the legs fully and at the same level without locking the knees keep a slight bend in the knees Maintain erect position on the Seat and Seat Back ECCENTRI...

Страница 14: ...ing guidelines START TEST Press and hold both Thumb Buttons until 6 r Test Mode displays in the RESISTANCE window then release the Thumb Buttons NOTE TARGET REPS window displays P1 Power Test Set 1 SE...

Страница 15: ...tions NOTE Your Keiser Air Compressor not included with your Air300 Leg Press requires basic annual maintenance Contact Keiser Customer Support for Air Compressor operator manual or download at keiser...

Страница 16: ...Box Pull and remove the cover 2 Remove the 2 D batteries by carefully pulling outtheBatterySleeve followmanufacturer s recommendations for handling maintaining and disposing of batteries 3 Observe th...

Страница 17: ...ubricate Cylinder Rods Wipe the Cylinder Rods clean and coat lightly with clean SAE 30 motor oil or with a silicon based spray 5 Replace the Mufflers one on each Cylinder if discoloration is present T...

Страница 18: ...with the disposal of waste products residues including disposal of the equipment itself at the end of its useful life The Air300 Leg Press contains electronic circuit assemblies 2 alkaline D cell batt...

Страница 19: ...ECTROMAGNETIC COMPATIBILITY EMC DISPOSAL This equipment contains electrical or electronic components alkaline batteries and a sealed lithium coin cell battery that must be disposed of properly to comp...

Страница 20: ...y If you have any questions about your warranty please contact Keiser Customer Support at 1 559 256 8000 and via live chat at keiser com support Monday Friday 9 am to 5 pm Pacific Time or by email at...

Отзывы: