USER MANUAL
Spirit User manual
page 11
Program hot water timer
1. Press-hold the push button underneath the left brew lever for 6 seconds (all indicator lights start
flashing), then release.
2. Within the next 20 seconds: press the hot water lever briefly to start flow. The indicator lights of
both groups will be lit continuously.
3. Press hot water lever again to stop flow when amount of water wanted is reached. The indicator
lights will start flashing again.
4. Briefly press the push button switch or wait 30 seconds to store the programmed volume and exit
the programming mode (the indicator lights go dim).
Start automatic back-flush program
See paragraph “
” on page 19 for complete back-flush procedure
.
1. Shut down machine by turning mains switch to
“OFF”.
2. Make sure that the toggle switch under the left hand group is in the left position (see Figure 7).
3. While pressing the left group lever down, turn
the mains switch to “NO HEAT” or “ON”.
4. The back-flush program will start (if it does not start, check position of toggle switch).
5. As soon as the program has ended, the main controller will return to normal operation (provided
that the mains switch is
in position “ON”). It may take a while for the boilers to reach the
programmed temperatures as a lot of cold water has flown into the system during back-flushing.
Figure 7. The toggle switch under the left hand
brew lever is positioned to the left.
left volume
switch ON
press down
left group