ECLIPSE – INSTALLATION/OPERATION MANUAL
Eclipse
Jan-10
7
With the AC/auxiliary sensor properly connected, on a call for air conditioning there is a 15
second time delay for the blower to come on slowly and the blower speed will modulate
according to the plenum temperature.
2.7 ASSEMBLE & INSTALL BURNER
ASSEMBLE
Check burner model is correct for furnace rating required. Assemble as
per burner manufacturer’s instructions.
SET END CONE
Riello – set turbulator as per furnace operating decal. Beckett – see
Burner Manufacturers Instructions.
SELECT NOZZLE
Select oil input, nozzle and burner configuration as shown on furnace
operating decal.
INSTALL NOZZLE
Install selected nozzle, check for clean seating and tighten in nozzle
adaptor.
TARGET WALL
If the furnace is equipped with a Beckett burner use the two piece
ceramic target wall included in the burner packaging. Install target wall
through burner opening ensuring that the target wall is positioned so that
it sits tightly against the back of the heat exchanger. The target wall
must be installed so that it sits on the bottom of the primary heat
exchanger.
ELECTRODES
See burner manufacturer’s instructions for correct setting.
INSERTION
See
section
6.0 GENERAL SPECIFICATIONS
or Figure – 1.
LENGTH
MOUNT BURNER
Tighten top nut first so burner tips down slightly. The burner is always
installed in an upright position by four (4) nuts.
PUMP BY-PASS
For one pipe system factory setting (no plug).
PLUG
WIRING
Refer to wiring label and Figure – 4, 5 or 6 (depending on which unit is
being installed) for correct burner connections.
Beckett Burners –
Beckett burners must have the igniters wired to
operate constantly while the burner motor is running. This is referred to
as intermittent ignition in the Beckett manual.
.
THERMOSTAT
Connect the thermostat terminals.
DO NOT
start the oil burner until installation is complete and all cleanout covers are securely in
place.
2.8 CHANGING
NOZZLE
NOZZLE CHANGE
If a new nozzle of a different size is installed, change the heating blower
speed according to the sections
3.0 BURNER SPECIFICATIONS
or
operating decal.