F96VTN and G96VTN: Installation, Start-up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
3
A210210
Fig. 1 – Dimensional Drawing
SAFETY CONSIDERATIONS
FURNACE SIZE
A
B
C
D
SHIP WT.
LB (KG)
CABINET WIDTH
OUTLET WIDTH
BOTTOM INLET WIDTH
AIR INTAKE
0401410
14-3/16 (361)
12-1/2 (319)
12-9/16 (322)
7-1/8 (181)
123 (55.8)
0601714
17-1/2 (445)
15-7/8 (403)
16 (406)
8-3/4 (222)
139 (63.0)
0801716
17-1/2 (445)
15-7/8 (403)
16 (406)
8-3/4 (222)
147 (66.7)
1002120
21 (533)
19-3/8 (492)
19-1/2 (495)
10-1/2 (267)
170 (77.1)
1002122
21 (533)
19-3/8 (492)
19-1/2 (495)
10-1/2 (267)
171 (77.6)
1202422
24-1/2 (622)
22-7/8 (581)
23 (584)
12-1/4 (311)
190 (86.2)
U.S. ECCN: Not Subject to Regulation (N.S.R.)
SD5660-4 REV. -
NOTE: ALL DIMENSIONS IN INCH (MM)
WARNING
!
FIRE, INJURY, OR DEATH HAZARD
Failure to follow this warning could result in property damage, personal
injury, or death.
This furnace was manufactured to operate with natural gas. When fuel
supply is Liquid Propane (LP), this furnace must be converted with a
factory approved LP conversion kit. See furnace rating plate for
approved conversion kit.
WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK, AND
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in dangerous operation,
personal injury, death, or property damage.
Improper installation, adjustment, alteration, service, maintenance, or
use can cause carbon monoxide poisoning, explosion, fire, electrical
shock, or other conditions which may cause personal injury or property
damage. Consult a qualified service agency, local gas supplier, or your
distributor or branch for information or assistance. The qualified
service agency must use only factory-authorized accessories and
replacement parts when installing and servicing this product.