background image

 

Models

 

EX17DT  (RHFE

-

436FTA)

 

EX22DT  (RHFE

-

570FTA)

 

General 

Description

 

Forced Combustion, Forced Convection, 

Flued Gas Furnace 

 

Application

 

• 

Approved for manufactured home 

(USA only), mobile home, or 

residential installation convertible for 

use with natural gas and liquefied 

petroleum gases (propane) when 

provision is made for the conversion 

from one gas to the other. 

 

• 

Approved for commercial setting.

 

• 

Approved for installation at altitudes 

up to 10,200 ft. (3,109 m). 

 

Supplied with 

Purchase

 

• 

Direct Vent Wall Furnace

 

• 

Flue Manifold "A" Vent Kit

2

 (FOT

-

151)

 

• 

Back Spacer Set

 

• 

Manual Gas Shut

-

off Valve

 

• 

Full Size Wall Template Located on 

Furnace Carton Box

 

• 

Installation and Wall Mounting 

Hardware

 

• 

Installation and Operation Manual

 

Optional Items

 

• 

Extension Kit

 

Extends the exhaust line and air 

intake hose between the flue manifold 

and furnace. 

 

• 

Remote Thermostat Installation Kit 

 

− 

Part # 

204000045 

for US 

installations

 

− 

Part # 

204000048 

for Canadian 

installations

 

• 

Gas Conversion Kit: 

 

EX17DT (RHFE

-

436FTA):

 

− 

Part # 

203000007 

for Converting to 

Natural Gas

 

− 

Part # 

203000008 

for Converting to 

Propane

 

EX22DT (RHFE

-

570FTA) and 

 

EX22DT

-

W (RHFE

-

570FTA

-

W):

 

− 

Part # 

203000009 

for Converting to 

Natural Gas

 

− 

Part # 

203000010 

for Converting to 

Propane

 

Location

 

Clearance

 

Top and Bottom/

Ground

 

0 in. (0 mm)

 

Front (Panel)

 

40 in. (1 m)

1

 

Back (Including 

Back Spacer)

 

0 in. (0 mm)

 

Sides (Left and 

Right)

 

2 in. (50 mm)

 

Does not include flooring material or carpeting 

less than 1.2 in. (30 mm) in height. 

 

Clearances to access the 
furnace during servicing are 
10 in. (254 mm) from the 
sides, 40 in. (1 m) from the 
front, and the area shown 
above the furnace in the 
figure to the left. 

 

Rinnai recommends 10 in. 
(254 mm) clearance from 
the top and on both sides 
for servicing.

 

Service Clearances

 

Kit Name

 

Kit No.

 

Fits Walls

 

S  Vent Kit

 

FOT

-

150

 

-

 4 1/2 in. (75 

-

 115 mm)

 

A  Vent Kit

 

FOT

-

151

 

4 1/2 

-

 9 1/2 in. (115 

-

 240 mm)

 

B  Vent Kit

 

FOT

-

152

 

9 1/2 

-

 15 3/4 in. (240 

-

 400 mm)

 

C  Vent Kit

 

FOT

-

153

 

15 3/4 

-

 23 5/8 in. (400 

-

 600 mm)

 

D  Vent Kit

 

FOT

-

154

 

23 5/8 

-

 31 1/2 in. (600 

-

 800 mm)

 

Additional flue manifolds are available for different wall 

thicknesses (purchased separately). Vent Kit 

A

” 

is included 

with the furnace. 

 

Top

 

Bottom

 

Side

 

Front

 

Back

 

clearance for
maintenance

inches 

 

(mm) 

 

 

(229)

 

6 (153)

 

3 (76)

 