2.2  WARNINGS AND CAUTIONS

Please note that the proper and safe functioning of our instruments is only guaranteed if 

both the instruments and their accessories are exclusively from Keeler Ltd. The use of other 

accessories may result in increased electromagnetic emissions or reduced electromagnetic 

immunity of the device and may lead to incorrect operation.
Observe the following precautions in order to ensure safe operation of the instrument.

WARNINGS

•  Never use the instrument if visibly damaged and periodically inspect it for signs of damage 

or misuse.

•  Check your Keeler product for signs of transport / storage damage prior to use.
•  Do not use in the presence of fl ammable gases / liquids, or in an oxygen rich environment.
•  US Federal Law restricts this device to sale by or on the order of a physician or practitioner.
•  This device is intended to be used only by suitably trained and authorised healthcare 

professionals.

•  This product should not be immersed in fl uid.
•  Repairs and modifi cations to the instrument must be made only by the specialized 

technicians of the manufacturer’s Technical Service Centre or by personnel trained and 

authorised by the manufacturer. The manufacturer declines any and all responsibility for 

loss and / or damages resulting from unauthorised repairs; furthermore, any such actions 

will invalidate the warranty.

•  The power switch and mains plug are the means of isolating the device from the mains 

supply - ensure both the power switch and mains plug are accessible at all times.

•  Do not position the equipment so that is diffi cult to press the power switch or remove the 

mains plug from the wall socket.

•  Refraction stand variants or adaptors should only be used in combination with EN/IEC 

60601-1 and EN/IEC 60601-1-2 compliant power supplies and devices. 

•  Route power cords safely to eliminate risk of tripping or damage to user.

•  Before any cleaning of the instrument or the base unit ensure the power lead is 

disconnected.

•  LEDs can reach high temperatures in use – allow to cool before handling.

•  Do not exceed maximum recommended exposure time.

•  Should the instrument suffer shocks (for example, should it accidentally fall), and the 

optical system or the illumination system are damaged it may be necessary to return the 

instrument to the manufacturer for repair.

Содержание H Series

Страница 1: ...SLIT LAMP INSTRUCTIONS FOR USE H Series A world without vision loss...

Страница 2: ......

Страница 3: ...R USE 11 6 1 SETTING THE BINOCULARS 11 6 2 PREPARING THE PATIENT AND USING THE SLIT LAMP 12 6 3 DESCRIPTION OF FILTERS APERTURES AND MAGNIFICATIONS 13 7 ROUTINE MAINTENANCE 14 7 1 LED SYSTEMS 14 7 2 R...

Страница 4: ...ty Humidity limitation Use by date Serial number Catalogue number Medical device Translation The Keeler Slit Lamp is designed and built in conformity with Directive 93 42 EEC Regulation EU 2017 745 an...

Страница 5: ...embly and a table top with power supply and accessory drawer The light intensity is controlled by a variable rheostat located on the XYZ translation base There are a number of selectable filters allow...

Страница 6: ...the specialized technicians of the manufacturer s Technical Service Centre or by personnel trained and authorised by the manufacturer The manufacturer declines any and all responsibility for loss and...

Страница 7: ...ortant when the unit has been stored or transported in a cold environment this can cause severe condensation to develop on the optical elements 2 3 CONTRAINDICATION There is no restriction to patient...

Страница 8: ...s 9 Power lead chinrest to lamp housing KSL H Series 10 Lamp cover 11 Lamp cover release screws 12 Lever for grey ND blue diffuser and red free filters 13 Slit length slit rotation and aperture contro...

Страница 9: ...8 R type tonometer mounting hole 29 Yellow filter knob up out 30 Lock for securing magnification body 31 Magnification change drum 32 Eyepieces adjustable for PD and dioptre correction 33 Breath shiel...

Страница 10: ...castors ensure the following before moving it to another location 1 The table is at its lowest position 2 The power cord is removed 3 The Slit Lamp arm and base locking knobs are tightened 4 The runn...

Страница 11: ...gned Attach the tower to the base using the hex bolt removed earlier and tighten using the wrench provided 2 Carefully fit the microscope body to the arm ensuring it is pushed to the stop Tighten usin...

Страница 12: ...n 9 4 Power Supply page 20 3 Connect the mains power to the Slit Lamp transformer using the power lead provided Only a hospital grade 3 conductor electrical power supply cable must be used For USA and...

Страница 13: ...sures exact centering of the prism with the left objective 8 To obtain an image as clear and as free of reflexes as possible the angle between the illumination and the microscope should be about 60 an...

Страница 14: ...nus one 1 or minus two 2 dioptres 6 2 PREPARING THE PATIENT AND USING THE SLIT LAMP Parts of the slit lamp coming in to contact with the patient should be cleaned in accordance with these instructions...

Страница 15: ...mination Tightening the knob will re centre the slit image in the centre of the visual field of the microscope 8 The slit image is made vertical or given a pre set angle by means of the inclination la...

Страница 16: ...e outlined below should only be carried out once the main power cable has been disconnected If you have any problems that are not covered by the procedures described below contact Keeler Ltd or your l...

Страница 17: ...ables and connectors To access the bulb connections see earlier in this section for guidance 7 5 OPTICS The optics should be wiped clean of any loose dirt or debris with a suitable dust brush then cle...

Страница 18: ...g or using this instrument please read carefully and observe what is described here Portable or mobile type radio frequency communication units may have an adverse effect on this instrument resulting...

Страница 19: ...1 kV line s to line s 2 kV line s for input output line s 1 kV line s to line s 2 kV line s for input output line s Mains power quality should be that of a typical professional healthcare facility Vol...

Страница 20: ...nd people 1 Field strengths from fixed transmitters such as base stations cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predict...

Страница 21: ...requency applies These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 9 4 TECHNICAL SPECIFICATIONS O...

Страница 22: ...provide at least two means of protection Power Supply Power supply unit Switch mode 100V 240V input 10 multi plug compliant to EN IEC 60601 1 EN IEC 61000 6 2 EN IEC 61000 6 3 Fuse T2 5AH 250V Power s...

Страница 23: ...60 hPa 700 hPa TRANSPORT CONDITIONS 50 C 40 C 95 10 1060 hPa 500 hPa Vibration sinusoidal 10 Hz to 500 Hz 0 5g Shock 30 g duration 6 ms Bump 10 g duration 6 ms This instrument does not meet the temper...

Страница 24: ...al Keeler Applanation Tonometer 2414 P 2032 Keeler D KAT R Type Digital Keeler Applanation Tonometer 2414 P 2042 11 PACKAGING AND DISPOSAL INFORMATION Disposal of old electrical and electronic equipme...

Страница 25: ......

Страница 26: ...2021 USA Sales Office Keeler USA 3222 Phoenixville Pike Building 50 Malvern PA 19355 USA Toll Free 1 800 523 5620 Tel 1 610 353 4350 Fax 1 610 353 7814 India Office Keeler India Halma India Pvt Ltd P...

Отзывы: