P30
Displays and operating elements
Operating instructions V3.22
16
© KEBA
4.2.2
Display with calibratable energy meter (MID)
If the charging station is marked as MID version on the type plate, the follow-
ing information is shown on the display:
Display
Description
Transmitted energy of the current charging process,
Display at start and after completion of a charging process
Text display, e.g. call for action or information about the charging
process
Calibration-relevant displays (MID) are provided with a special mark:
Display
Description
Sum of total transmitted energy,
Display during start-up of the charging station as well as at the start
and after completion of a charging process
Displays of the firmware version,
Display when starting up the charging station and when starting a
charging process
1. "MID"
2. Firmware version
3. Build version
4. Checksum
On the left is an example of the firmware version 12.34.56.
If the display is marked with a preceding "M!", an internal message
was stored in the memory of the charging station during the charging
process. When restarting the charging station, the marking is reset.
MID-relevant error. The charging station must be returned for repair.