3-14
Operating Instructions CDF3000
3 Installation
3.6
Serial interface
(SIO)
The serial interface (SIO, X4) is used to connect a K
EY
P
AD
with S
MART
-
C
ARD
or a notebook with the PC-Tool D
RIVE
M
ANAGER
installed. This can
be used to parameterize the CDF3000.
Fig. 3.8
Terminal X4
Please use only the prefabricated RS232 cable CCD-SUB 90X (max.
length 3 m) to connect the positioning controller.
Pin assignment X4
Attention:
The RS232
interface must only be
used for service and
commissioning. Using
the interface for control
purposes is not
permitted.
G
rundein
s
tellungen...
Voreingestellte Lösungen:
Er
s
tinbetriebnahme...
Erweitert >>
I
s
twerte ...
Fehler/Warnung ...
Ein
s
tellung in Datei
s
peichern
Hilfe
Abbbrechen
Taktantrieb, Eil-/
S
chleichgang
C:\Pro
g
ramme\Lu
s
t Antrieb
s
technik GmbH\LU
S
T DriveMana
g
er\u
s
e...
X
D
RIVE
M
ANA
GER
3
m m
a
x.
R
S
2
3
2
R
S
2
3
2
CCD-
S
UB90X
X4
Parameter
s
tart
enter
s
top
return
VAL
Hz
543
2
1
98
7
6
X4
SIO
Pin-No.
Function
1
+15 V DC for control unit KP200XL
2
TxD, data transmission
3
RxD, data reception
4
Do not use
5
GND for +15 V DC of the control unit KP200XL
6
Do not use
7
Do not use
8
Do not use
9
Do not use
Table 3.8
Pin assignment of the serial interface X4
Содержание CDF3000
Страница 1: ...Positioning controller Rated current 8 A Power supply 24 48 V DC CDF3000 Operation Manual...
Страница 12: ...Operating Instructions CDF3000...
Страница 16: ...1 4 Operating Instructions CDF3000 1 Safety...
Страница 54: ...3 34 Operating Instructions CDF3000 3 Installation...
Страница 78: ...4 24 Operating Instructions CDF3000 4 Commissioning...
Страница 84: ...5 6 Operating Instructions CDF3000 5 Troubleshooting...