![Keba CDF3000 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/keba/cdf3000/cdf3000_operation-manual_3828484032.webp)
3-12
Operating Instructions CDF3000
3 Installation
3.5.2 Connection of
2nd encoder to
X6
A SSI encoder can be evaluated on X6, parallel to the resolver connec-
tion (see chapter 3.5).
During simultaneous use the Fig. 3.7SSI-encoder must solely be used for
the positioning controller, as described in Fig. 3.7.
Motor commutation and lower level speed regulation in this case takes
place via the resolver.
Fig. 3.7
Drive with two measuring systems
3.5.3 Motor tempera-
ture monitoring
For thermal monitoring of the motor winding a PTC-thermistor can be
connected to X 6/9 and 10 via the encoder line. The type used must be
set in parameter 330-MOPTC during commissioning (factory default set-
ting is "off").
15
-
CLK-
B-
X6-
Pin
Function Resolver
Function SSI
Function TTL
Table 3.6
Assignment of encoder interface X6
M
SSI
position
speed
Resolver
DRIVE
X6
Sensor
Technical data
no PTC
used
Standard
PTC
linear voltage
evaluation
TSS,
Thermostatic
circuit breaker
Usable type
–
PTC to
DIN44082
KTY84-130,
(tolerance band
yellow) *
Klixon
Parameter
330-MOPTC =
OFF
DIN
KTY
TSS
Table 3.7
Motor temperature monitoring specification
Содержание CDF3000
Страница 1: ...Positioning controller Rated current 8 A Power supply 24 48 V DC CDF3000 Operation Manual...
Страница 12: ...Operating Instructions CDF3000...
Страница 16: ...1 4 Operating Instructions CDF3000 1 Safety...
Страница 54: ...3 34 Operating Instructions CDF3000 3 Installation...
Страница 78: ...4 24 Operating Instructions CDF3000 4 Commissioning...
Страница 84: ...5 6 Operating Instructions CDF3000 5 Troubleshooting...