33
cONNEcTION
4.5 Encoder connection
WARNING
Subsequent adjustment of the measuring system
Malfunction and uncontrolled reactions of the motor !
The measuring system of the synchronous motors is factory-adjusted to
the respective drive controller. Any mis-adjustment may lead to uncon-
trolled motor response or complete failure of the motor.
In order to avoid any risk, the motor must be put into operation only in
no-load operation, without connection to the system.
4.5.1 Resolver terminal assignment
Description
View
Pin No.
Signal
colour
View to the
connector pins of the
resolver connector
at the motor
1
9
8
7
12
6
10
2
3
4
11
5
1
SIN-
red
2
COS-
pink
5
REF-
yellow
7
REF+
green
10
SIN+
blue
11
COS+
grey
All unspecified contacts are not
assigned.
Figure 9:
Resolver terminal assignment
Drive controller series
Required encoder cable
COMBIVERT
F6
00S6L50-10yy
1)
S6
Table 7:
Resolver encoder cable
1)
Assembled, shielded, towable, yy = cable length in metres.