3.3.3 Connection of the digital inputs
With internal voltage supply
With external voltage supply
12
11
6 8 10
5
4
3
7 9
12
11
6 8 10
5
4
3
7 9
+
Input
factory setting of the digital inputs
Name
PIN
Open-loop operation
Closed-loop operation
RST
5
Reset
ST
6
Control release
R
7
Reverse direction of rotation
F
8
Forward direction of rotation
I1
10
Fixed frequency 1
Fixed frequency 3
Fixed value 1
Fixed value 3
I2
9
Fixed frequency 2
Fixed value 2
I3
12
External error input (E.EF)
I4
11
Activates the DC braking
–
Figure 9:
Connection of the digital inputs
3.3.4 Connection of the digital outputs
Connection appliance
Connection to an external control
15
13
14
15
13
14
COM
DI1
DI2
Figure 10: Example for the control of digital inputs and outputs
continued on the next page
22
CONTROL CIRCUIT ANALOG/DIGITAL