![KEB COMBIVERT 10F6 Series Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/keb/combivert-10f6-series/combivert-10f6-series_instructions-for-use-manual_660354037.webp)
37
DeVIce DATA OF THe 230 V DeVIceS
Device size
12
rated switching frequency
4 kHz
Output frequency
f
out
/ Hz
0
3
6
12.5
25
50
Frequency-dependent maximum current @
f
S
Basic Time Period = 62.5 µs (Parameter is22=0)
I
lim
/ %
2 kHz
4 kHz
8 kHz
16 kHz
Frequency-dependent maximum current @
f
S
Basic Time Period = 71.4 µs (Parameter is22=1)
I
lim
/ %
1.75 kHz
3.5 kHz
TBD
7 kHz
14 kHz
Frequency-dependent maximum current @
f
S
Basic Time Period = 83.3 µs (Parameter is22=2)
I
lim
/ %
1.5 kHz
3 kHz
6 kHz
12 kHz
Frequency-dependent maximum current @
f
S
Basic Time Period = 100 µs (Parameter is22=3)
I
lim
/ %
1.25 kHz
2.5 kHz
5 kHz
10 kHz
Table 15:
Frequency-dependent maximum current for device size 12
Device size
13
rated switching frequency
4 kHz
Output frequency
f
out
/ Hz
0
3.1
6.2 12.5
25
50
Frequency-dependent maximum current @
f
S
Basic Time Period = 62.5 µs (Parameter is22=0)
I
lim
/ %
2 kHz
4 kHz
8 kHz
16 kHz
Frequency-dependent maximum current @
f
S
Basic Time Period = 71.4 µs (Parameter is22=1)
I
lim
/ %
1.75 kHz
3.5 kHz
TBD
7 kHz
14 kHz
Frequency-dependent maximum current @
f
S
Basic Time Period = 83.3 µs (Parameter is22=2)
I
lim
/ %
1.5 kHz
3 kHz
6 kHz
12 kHz
Frequency-dependent maximum current @
f
S
Basic Time Period = 100 µs (Parameter is22=3)
I
lim
/ %
1.25 kHz
2.5 kHz
5 kHz
10 kHz
Table 16:
Frequency-dependent maximum current for device size 13