5.3 Parameters of the PROFIBUS interface
The parameters serve for the configuration of the PROFIBUS interface. The parameters are
addressed via PROFIBUS by means of index (16 bit) and subindex (8 bit).
Name
Fieldbus Comm Axis
Meaning
Serves for change-over of the PROFIBUS communication between
each devices, which can be addressed by the control.
Index
5FFFh
Subindex
0
Data length
1 Byte
Coding
0
The control itself is addressed.
1…8 Axis 1…8 is addressed
Default
0
Note
A changed value is immediately active. After switching on the para-
meter value is always = 0.
Name
Parameter of the respective ax
is
Meaning
set-addressing
Index
2000…5FFEh
Subindex
0
Data length
1 Byte
Coding
0
indirect set-addressing
1…255 binary coded set-addressing set 0...7