CLEANING CABINET 

The front, back and sides of the cabinet should be kept 
clean for sanitary reasons.

CARE OF THE MIRACLEAN® SURFACE

The Miraclean® surface is very hard. With proper care,
the MIRACLEAN® surface and its unique cooking
properties will last for many years. 

„

NEVER USE A GRIDDLE STONE, BRICK OR
SCREEN TO CLEAN THE MIRACLEAN®
SURFACE. DAMAGE DONE TO THE
MIRACLEAN® SURFACE BY GRIDDLE STONE,
BRICK OR SCREEN WILL VOID THE WARRANTY.

„

DO NOT HACK, CHOP, HIT OR CUT ON THE
MIRACLEAN® SURFACE. YOU WILL DENT THE
STEEL

PLATE UNDER THE TRIVALENT

CHROME. IT IS EVEN POSSIBLE TO HACK TWO
NICKS CLOSE TOGETHER AND ACTUALLY
TEAR THE MIRACLEAN® SURFACE AS THE
CHROMIUM WILL NOT STRETCH. PROPER USE
OF THE UTENSILS SUPPLIED WITH YOUR
MIRACLEAN® GRIDDLE WILL

PREVENT

SURFACE DAMAGE. THE DAMAGE DONE TO
THE MIRACLEAN® SURFACE IS IRREPARABLE.

„

NEVER USE ICE TO COOL THE MIRACLEAN® 
SURFACE. USE OF ICE MAY WARP THE
MIRACLEAN® SURFACE.

„

USE ONLY KEATING SUPPLIED CLEANING 
TOOLS AND KLENZER.

„

USE ONLY A KEATING STEEL SPATULA.

„

DO NOT CLEAN SCRAPER ON SPLASHBACK,
GREASE BUILD-UP WILL OCCUR WHICH MAY
RESULT IN A FIRE.

„

DO NOT OBSTRUCT THE FLUE. THE FLUE HAS
BEEN DESIGNED SPECIFICALLY TO EXHAUST
THE BY-PRODUCT OF ANY COMBUSTION. ANY
OBJECTS (STEAK WEIGHTS, EGG COVERS,
PANS, RAGS, UTENSILS, ETC.) PLACED ON THE
FLUE WILL INHIBIT THE PROPER COMBUSTION
AND EXHAUST, THEREFORE CAUSING HEALTH
HAZARDS.

„

DO NOT USE A POWER WASH, HOSE OR STEAM
CLEANER FOR DAILY CLEANING.

THERMOSTAT CALIBRATION

Calibration is not covered under warranty.

Tools: Accurate surface thermometer

Standard screwdriver

1. Turn the exhaust system ON.
2. Turn on the griddle with thermostat set at 300°F.

Allow burners to cycle on and off three times.
(Approximately 60 minutes.)

3. Place accurate thermometer on surface over

thermostat bulb. Use the inverted “V” on the front
of the griddle plate to locate thermostat bulb.
Place the surface thermometer about half way

toward the back of the plate.

4. When burners cycle off, the griddle is up to

temperature. If temperature is within 25°F of
thermostat setting, remove knob. Loosen four
screws in the thermostat dial plate. Replace knob.
Reset the dial plate to match the thermometer
reading.

Thermostat calibration

Thermostat knob removed to reveal calibration screws.

5. Remove the knob to tighten screws on dial plate

and replace the knob.

For calibration over a 50°F difference, contact a
qualified service company.

CONDITIONING THE 

MIRACLEAN® GRIDDLE PLATE

The Miraclean® Griddle plate has been “seasoned” at
the factory. The Miraclean® surface when heated
creates a thin layer of chrome oxide which acts as a
releasing agent for food product. You may feel that you
need to recondition your griddle surface.
1.  Follow cleaning instructions on page 5.

2.  Heat the MIRACLEAN® to 400°F for one hour.

3. Lower thermostat to 350°F, allowing the

MIRACLEAN® to cool to about 350°F, as is evident
when griddle cycles on or surface thermometer
indicates correct temperature.

4.  Lightly coat the MIRACLEAN® surface with griddle

oil.

NOTE: 

Despite the food releasing properties, the

chrome surface is not a true “non-stick” surface. For
best cooking results and product appearance, use
griddle oil for products that require the surface to be
conditioned.

PARTS ORDERING

Parts may be ordered by part number by calling
Keating at 1-800-KEATING or your service company.
You may also order on-line at Keating’s part store,
www.keatingofchicago.com.
Refer to the Keating MIRACLEAN® Griddle Limited
Warranty for complete service and ordering
information.
The model/serial plate is located inside the grease
drawer housing on the side. The model and serial
numbers are necessary when ordering.

6

Содержание Miraclean 2000

Страница 1: ...tions 1 Damage in Shipment 1 Positioning 1 Ventilation 1 National Code Requirements 1 Gas Connections and Pipe Size 2 Flexible Gas Connections Quick Disconnect Devices 2 Leveling 2 Lighting Instructio...

Страница 2: ...GAS MAY EVENTUALLY LOSE ITS ODOR AND PRECAUTIONS SHOULD BE TAKEN TO ASSURE THAT PROPANE GAS IS NOT PRESENT EVEN THOUGH YOU DO NOT DETECT AN ODOR IF THERE IS ANY DOUBT YOU SHOULD CALL YOUR LOCAL PROPAN...

Страница 3: ...y the carrier DO NOT RETURN DAMAGED MERCHANDISE TO KEATING FILE YOUR CLAIM AS ABOVE FIRST STEPS POSITIONING Keep appliance area free and clear of any combustibles Position the Miraclean Griddle 6 inch...

Страница 4: ...cal gas company to assure adequate volume and pressure Refer to serial plate for proper gas requirement for your particular model FLEXIBLE GAS CONNECTORS AND QUICK DISCONNECT DEVICES For an appliance...

Страница 5: ...heat of the Miraclean has an emissivity of 078 You can prove this to yourself by holding your hand approximately 1 2 above the Miraclean Griddle plate At this distance it is difficult to tell whether...

Страница 6: ...quality food products Follow cooking procedures below COOKING INSTRUCTIONS 1 Set the thermostat to the desired temperature and wait ten minutes for preheat The operating temperature should be from 10...

Страница 7: ...ith Keating Klenzer Polish with a soft cloth towel It will sparkle like new in just a few minutes Rinse with potable water to remove excess Keating Klenzer Proper care should be taken to fully clean t...

Страница 8: ...urate thermometer on surface over thermostat bulb Use the inverted V on the front of the griddle plate to locate thermostat bulb Place the surface thermometer about half way toward the back of the pla...

Страница 9: ...TEM DESCRIPTION PART NUMBER 1 SPARK IGNITION ASSEMBLY SEE Item 4 Figure 6 2 2 THERMOPILE 022770 3 PILOT TUBE 1 4 007998 4 PILOT ASSEMBLY 029769 ALL NATURAL GAS 24 30 029599 LP 24 39 BEF NATURAL GAS OR...

Страница 10: ...the screws 2 Disconnect the wires on the switch and remove switch 3 Snap the new switch into place and reconnect all wires 4 Return the control panel to its normal position THERMOSTAT REMOVAL AND REPL...

Страница 11: ...having a 1 1000MV range Conduct each check below by connecting meter test leads to terminals as indicated All readings are closed circuit A BURNER COIL CHECK A Reading Thermostat contacts CLOSED Gas V...

Страница 12: ...een 75 millivolts and 25 millivolts If dropout occurs outside these limits change the valve WARNING AND OPERATING PLATES All warning and operating plates on the Keating MIRACLEAN Griddle should be in...

Страница 13: ...e to 4 e Gas valve failure e Replace valve Temperature of a Thermostat is not calibrated a Calibrate thermostat with exhaust griddle erratic system running b Air from exhaust hood excessive b Have exh...

Страница 14: ...TY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installation or main...

Страница 15: ...________________________ ADDRESS ______________________________________________________________________________________________________ CITY ___________________________________________________________...

Отзывы: