manualshive.com logo in svg
background image

GAS CONNECTIONS AND PIPE SIZE

The Miraclean® Griddle requires a standard gas pipe
size of 3/4 inch (19mm) I.D. connection. The size of the
gas supply pipe is very important if the pipe is too small
you will have low gas pressure at the Miraclean®
Griddle manifold. Low gas pressure will cause slow
recovery and/or delayed ignition. If you have a question
about gas pipe size call your local gas company.

CAUTION

Before connecting new pipe to the Miraclean® Griddle
the pipe must be blown out to remove all foreign
particles. These particles in the controls or burners may
cause improper or dangerous operating conditions.

CAUTION

Pipe joint compounds that are used on threaded joints
of appliance piping shall be resistant to the action of
liquified petroleum gases. When using pipe joint
compound do not apply to the first two threads. Use
only very small amount and only on male threads. This
will prevent clogging of burner orifices and the gas
valve. Never use compound on female threads as it
might be pushed into the gas valve.
Have your installer check for gas leaks using a soap
and water solution before operating. DO NOT USE AN
OPEN FLAME TO CHECK FOR GAS LEAKS.
1) The Miraclean® Griddle and its individual shut off
valves must be disconnected from the gas supply
piping system during any pressure  testing of that
system at test pressures in excess of 1/2 psi (3.45kPa)
(13.84 in WC) High pressure can damage the gas
valve causing a hazardous condition.

2.) The appliance must be isolated
from the gas supply piping system by
closing its individual manual shutoff
valve during any pressure testing of
the gas supply piping system at test
pressures equal to or less than 1/2 psi
(3.45 kPa). 
The required gas pressure for proper
operation of each Miraclean® Griddle
is 4" water column for natural gas and

10" water column for propane gas at the manifold.
If more than one gas unit is on the same supply line,
you may require a larger line. Consult your local gas
company to assure adequate volume and pressure.
Refer to serial plate for proper gas requirement for your
particular model.

FLEXIBLE GAS CONNECTORS AND QUICK

DISCONNECT DEVICES

For an appliance equipped with casters:
The installation shall be made with a connector that
complies with the Standard for Connectors for Movable
Gas Appliances, ANSI Z21.69 or the Standard for
Connectors for Moveable Gas Appliances, CAN/CGA-
1.16, and a quick disconnect device that complies with
the Standard for Quick-Disconnect Devices for Use
With Gas Fuel, ANSI Z21.41 or the Standard for Quick
Disconnect devices for Use with Gas Fuel, CAN1-6.9. 

RESTRAINING DEVICES

Adequate means must be provided to
limit the movement of the appliance
without depending on the connector
and the quick-disconnect device or its
associated piping to limit the
appliance movement.
Griddle installation on stands with
caster, casters and jam nuts must be
completely tightened.
The restraint means must be attached

to the rear of the Miraclean® Griddle within 2" of the
center line and approximately 1-5/8" from the bottom of
the cabinet back to allow the restraining bolt to be
anchored to the cabinet back between the cabinet
bottom and inner liner to ensure positive support to
restrain Miraclean® Griddle movement and not depend
on the flexible gas connector, quick-disconnect or
piping to limit the Miraclean® Griddle movement.
If disconnection of the restraint is necessary, it must be
reconnected when the Miraclean® Griddle is returned
to its originally installed position.

LEVELING

The Miraclean® Griddle will operate at its highest
efficiency when properly leveled. Place a level on the
Miraclean® Griddle plate from side to side. For griddles
on legs, the bottom foot of the leg is adjustable. Turn
counterclockwise to decrease height, or clockwise to
increase height until level. For griddles on stands with
casters, the casters are adjustable by loosening the
jam nut. When the desired level is reached, tighten the
jam nut. Adjustments of more than 3/4" are not
recommended on any caster. The same procedure
should be followed to level the Miraclean® Griddle from
front to back.

2

Содержание Miraclean 2000

Страница 1: ...tions 1 Damage in Shipment 1 Positioning 1 Ventilation 1 National Code Requirements 1 Gas Connections and Pipe Size 2 Flexible Gas Connections Quick Disconnect Devices 2 Leveling 2 Lighting Instructio...

Страница 2: ...GAS MAY EVENTUALLY LOSE ITS ODOR AND PRECAUTIONS SHOULD BE TAKEN TO ASSURE THAT PROPANE GAS IS NOT PRESENT EVEN THOUGH YOU DO NOT DETECT AN ODOR IF THERE IS ANY DOUBT YOU SHOULD CALL YOUR LOCAL PROPAN...

Страница 3: ...y the carrier DO NOT RETURN DAMAGED MERCHANDISE TO KEATING FILE YOUR CLAIM AS ABOVE FIRST STEPS POSITIONING Keep appliance area free and clear of any combustibles Position the Miraclean Griddle 6 inch...

Страница 4: ...cal gas company to assure adequate volume and pressure Refer to serial plate for proper gas requirement for your particular model FLEXIBLE GAS CONNECTORS AND QUICK DISCONNECT DEVICES For an appliance...

Страница 5: ...heat of the Miraclean has an emissivity of 078 You can prove this to yourself by holding your hand approximately 1 2 above the Miraclean Griddle plate At this distance it is difficult to tell whether...

Страница 6: ...quality food products Follow cooking procedures below COOKING INSTRUCTIONS 1 Set the thermostat to the desired temperature and wait ten minutes for preheat The operating temperature should be from 10...

Страница 7: ...ith Keating Klenzer Polish with a soft cloth towel It will sparkle like new in just a few minutes Rinse with potable water to remove excess Keating Klenzer Proper care should be taken to fully clean t...

Страница 8: ...urate thermometer on surface over thermostat bulb Use the inverted V on the front of the griddle plate to locate thermostat bulb Place the surface thermometer about half way toward the back of the pla...

Страница 9: ...TEM DESCRIPTION PART NUMBER 1 SPARK IGNITION ASSEMBLY SEE Item 4 Figure 6 2 2 THERMOPILE 022770 3 PILOT TUBE 1 4 007998 4 PILOT ASSEMBLY 029769 ALL NATURAL GAS 24 30 029599 LP 24 39 BEF NATURAL GAS OR...

Страница 10: ...the screws 2 Disconnect the wires on the switch and remove switch 3 Snap the new switch into place and reconnect all wires 4 Return the control panel to its normal position THERMOSTAT REMOVAL AND REPL...

Страница 11: ...having a 1 1000MV range Conduct each check below by connecting meter test leads to terminals as indicated All readings are closed circuit A BURNER COIL CHECK A Reading Thermostat contacts CLOSED Gas V...

Страница 12: ...een 75 millivolts and 25 millivolts If dropout occurs outside these limits change the valve WARNING AND OPERATING PLATES All warning and operating plates on the Keating MIRACLEAN Griddle should be in...

Страница 13: ...e to 4 e Gas valve failure e Replace valve Temperature of a Thermostat is not calibrated a Calibrate thermostat with exhaust griddle erratic system running b Air from exhaust hood excessive b Have exh...

Страница 14: ...TY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installation or main...

Страница 15: ...________________________ ADDRESS ______________________________________________________________________________________________________ CITY ___________________________________________________________...

Отзывы: