GAS VALVE 

REGULATOR ADJUSTMENT

Recommended gas pressure at manifold 

(4.0" W.C. Natural gas 10.0" W.C. Propane gas)

Adjustment of the gas valve pressure regulator is not
normally necessary since it has been preset at the
factory. During installation, the gas pressure should be
checked at each gas valve with all burners operating.
Adjustment may be accomplished as follows:
This adjustment must be performed by a qualified
technician.
1. Locate the gas valves. 
2. With the griddle turned off, connect the monometer

to the pressure tap on the gas valve to be tested.

3. Turn the unit on and take the reading after all the

burners have ignited.

4. Make the necessary adjustments by removing the

screw cap on the pressure regulator cover exposing
the adjustment screw (clockwise will increase the
pressure, counterclockwise will decrease the
pressure).

Always check the screw cap on the pressure tap for
leaks after it has been removed and replaced.

GAS VALVE 

REMOVAL AND REPLACEMENT

Disconnect the griddle from the gas supply.
1. Lower the control panel. Remove the control panel

surround and upper heat shield.

2. Remove the three wires connected to the gas

valve.

3. Disconnect the pilot and burner feed from the front

of the gas valve.

4. Access the pipe union at the rear of the gas valve

either from the front of the griddle or remove the
back of the cabinet and loosen the union.

5. Remove two nuts on the rear of the gas manifold

and pull the gas manifold forward.

6. Remove the gas valve and transfer the pipe and

fittings to the new gas valve. Transfer the pressure
tap to the new gas valve.

7. Replace the gas valve by reversing the above

steps.

Always check for leaks at all joints and connections
using a soap solution mixed with water. 
DO NOT USE AN OPEN FLAME TO CHECK FOR
GAS LEAKS. 
Double check the wire connections to the gas valve;
improper connection could damage the gas valve.

ON/OFF SWITCH 

REMOVAL AND REPLACEMENT

1. Lower the control panel by removing the screws. 
2. Disconnect the wires on the switch and remove

switch.

3. Snap the new switch into place and reconnect all

wires.

4. Return the control panel to its normal position.

THERMOSTAT 

REMOVAL AND REPLACEMENT

1. Lower the control panel by removing the

mounting screws.

2. Locate the bulb end of the thermostat and, using

a wrench, loosen the front and rear bolts holding
the thermostat bulb and shield in place.

3. Slide the thermostat bulb assembly towards you

and remove it from under the griddle plate.

4. Remove the knob and the screws from the

thermostat dial plate on the control panel.

5. Remove the body of the thermostat.
6. Install the new thermostat in the control panel,

replace the dial plate.

7. Slide the thermostat bulb assembly into the

channel until it reaches the stop.

8. Make sure that the thermostat capillary and bulb

are completely protected by the shield, except for
1” at the tip of the thermostat bulb. (See Note 1).

9. Make sure that the thermostat shield extends to

the front edge of the plate, and that the capillary
goes through the formed end of the shield. (See
Note 2).

10. Make sure that the bolts which hold the

thermostat bulb and shield in place do not touch
the thermostat bulb. (See Note 3).
Tighten bolts 1/4 turn past finger tight bulb to be
snug against the bottom of the plate.

DO NOT OVERTIGHTEN THE BOLTS ON THE
THERMOSTAT SHIELD OR THEY WILL
CRUSH THE THERMOSTAT BULB.   

11. Close the control panel and replace the panel

mounting screws.

NOTE:

IF REPLACING PUSH-ON TERMINAL

STYLE.  Before installing thermostat into control
panel, you must unscrew the two brass terminal
screws and install the new ring terminal wire
connectors. Prior to connecting these wires, the
existing push-on terminal must be cut off and ring
terminals installed on them. Make sure that the
terminals are secured down.

12. Calibrate the thermostat using an accurate

griddle thermometer. Locate the thermometer
over the thermostat bulb (shown by the "

Λ

" on

the front of the griddle plate) about half way
toward the back of the plate. Calibrate to the
cooking temperature you will be setting on the
thermostat.

See Page 9 for 
Proper Placement of the Thermostat Bulb

8

Содержание Miraclean 2000

Страница 1: ...tions 1 Damage in Shipment 1 Positioning 1 Ventilation 1 National Code Requirements 1 Gas Connections and Pipe Size 2 Flexible Gas Connections Quick Disconnect Devices 2 Leveling 2 Lighting Instructio...

Страница 2: ...GAS MAY EVENTUALLY LOSE ITS ODOR AND PRECAUTIONS SHOULD BE TAKEN TO ASSURE THAT PROPANE GAS IS NOT PRESENT EVEN THOUGH YOU DO NOT DETECT AN ODOR IF THERE IS ANY DOUBT YOU SHOULD CALL YOUR LOCAL PROPAN...

Страница 3: ...y the carrier DO NOT RETURN DAMAGED MERCHANDISE TO KEATING FILE YOUR CLAIM AS ABOVE FIRST STEPS POSITIONING Keep appliance area free and clear of any combustibles Position the Miraclean Griddle 6 inch...

Страница 4: ...cal gas company to assure adequate volume and pressure Refer to serial plate for proper gas requirement for your particular model FLEXIBLE GAS CONNECTORS AND QUICK DISCONNECT DEVICES For an appliance...

Страница 5: ...heat of the Miraclean has an emissivity of 078 You can prove this to yourself by holding your hand approximately 1 2 above the Miraclean Griddle plate At this distance it is difficult to tell whether...

Страница 6: ...quality food products Follow cooking procedures below COOKING INSTRUCTIONS 1 Set the thermostat to the desired temperature and wait ten minutes for preheat The operating temperature should be from 10...

Страница 7: ...ith Keating Klenzer Polish with a soft cloth towel It will sparkle like new in just a few minutes Rinse with potable water to remove excess Keating Klenzer Proper care should be taken to fully clean t...

Страница 8: ...urate thermometer on surface over thermostat bulb Use the inverted V on the front of the griddle plate to locate thermostat bulb Place the surface thermometer about half way toward the back of the pla...

Страница 9: ...TEM DESCRIPTION PART NUMBER 1 SPARK IGNITION ASSEMBLY SEE Item 4 Figure 6 2 2 THERMOPILE 022770 3 PILOT TUBE 1 4 007998 4 PILOT ASSEMBLY 029769 ALL NATURAL GAS 24 30 029599 LP 24 39 BEF NATURAL GAS OR...

Страница 10: ...the screws 2 Disconnect the wires on the switch and remove switch 3 Snap the new switch into place and reconnect all wires 4 Return the control panel to its normal position THERMOSTAT REMOVAL AND REPL...

Страница 11: ...having a 1 1000MV range Conduct each check below by connecting meter test leads to terminals as indicated All readings are closed circuit A BURNER COIL CHECK A Reading Thermostat contacts CLOSED Gas V...

Страница 12: ...een 75 millivolts and 25 millivolts If dropout occurs outside these limits change the valve WARNING AND OPERATING PLATES All warning and operating plates on the Keating MIRACLEAN Griddle should be in...

Страница 13: ...e to 4 e Gas valve failure e Replace valve Temperature of a Thermostat is not calibrated a Calibrate thermostat with exhaust griddle erratic system running b Air from exhaust hood excessive b Have exh...

Страница 14: ...TY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installation or main...