manualshive.com logo in svg
background image

MIRACLEAN

®

2000

GAS GRIDDLE

INSTALLATION MANUAL

USER OPERATION 

and

MAINTENANCE

SERVICE INSTRUCIONS

1-800-KEATING 

www.keatingofchicago.com

“Serving Those Who Serve The Very Best”

®

READ AND SAVE THIS MANUAL FOR FUTURE REFERENCE

Record the Model No. and Serial No. of this Miraclean® Griddle in the space provided below.
Serial No. 
Model No. 
Keep these numbers for future reference.

IMPORTANT: 

Keep a copy of your bill of sale. The date on the bill establishes the warranty period should

service be required. If service is performed, it is in your best interest to obtain and keep all receipts.

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Installation Instructions  . . . . . . . . . . . . . . . . . . . .1
Damage in Shipment . . . . . . . . . . . . . . . . . . . . . . .1
Positioning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Ventilation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
National Code Requirements  . . . . . . . . . . . . . . . .1
Gas Connections and Pipe Size  . . . . . . . . . . . . . .2
Flexible Gas Connections & Quick 

Disconnect Devices  . . . . . . . . . . . . . . . . . . . . .2

Leveling  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Lighting Instructions . . . . . . . . . . . . . . . . . . . . . . .3

Shutdown  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Cooking  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Preventative Maintenance . . . . . . . . . . . . . . . . . . .5
Avoid Service Checklist  . . . . . . . . . . . . . . . . . . . .5
Cleaning Care & Conditioning  . . . . . . . . . . . . . .5,6
Thermostat Calibration  . . . . . . . . . . . . . . . . . . . . .6
Service Parts Ordering . . . . . . . . . . . . . . . . . . . .6-7
Parts List  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Thermostat Removal & Replacement  . . . . . . . .8-9
Service Diagnosis/Trouble Shoot Chart  . . . . .9-11
Wiring Diagram  . . . . . . . . . . . . . . . . . . . . . . . . . .11

This Owner’s Guide provides specific operating instructions for your model. 

Versión en español

Si desea obtener una copia en español de este Manual del Usuario, 

sírvase escribir la dirección que se incluye a continuadión. 

*As continuous product improvement occurs, specifications may be changed without notice.

CONTENTS

GasGrid 2000

9/05

037399

Содержание Miraclean 2000

Страница 1: ...tions 1 Damage in Shipment 1 Positioning 1 Ventilation 1 National Code Requirements 1 Gas Connections and Pipe Size 2 Flexible Gas Connections Quick Disconnect Devices 2 Leveling 2 Lighting Instructio...

Страница 2: ...GAS MAY EVENTUALLY LOSE ITS ODOR AND PRECAUTIONS SHOULD BE TAKEN TO ASSURE THAT PROPANE GAS IS NOT PRESENT EVEN THOUGH YOU DO NOT DETECT AN ODOR IF THERE IS ANY DOUBT YOU SHOULD CALL YOUR LOCAL PROPAN...

Страница 3: ...y the carrier DO NOT RETURN DAMAGED MERCHANDISE TO KEATING FILE YOUR CLAIM AS ABOVE FIRST STEPS POSITIONING Keep appliance area free and clear of any combustibles Position the Miraclean Griddle 6 inch...

Страница 4: ...cal gas company to assure adequate volume and pressure Refer to serial plate for proper gas requirement for your particular model FLEXIBLE GAS CONNECTORS AND QUICK DISCONNECT DEVICES For an appliance...

Страница 5: ...heat of the Miraclean has an emissivity of 078 You can prove this to yourself by holding your hand approximately 1 2 above the Miraclean Griddle plate At this distance it is difficult to tell whether...

Страница 6: ...quality food products Follow cooking procedures below COOKING INSTRUCTIONS 1 Set the thermostat to the desired temperature and wait ten minutes for preheat The operating temperature should be from 10...

Страница 7: ...ith Keating Klenzer Polish with a soft cloth towel It will sparkle like new in just a few minutes Rinse with potable water to remove excess Keating Klenzer Proper care should be taken to fully clean t...

Страница 8: ...urate thermometer on surface over thermostat bulb Use the inverted V on the front of the griddle plate to locate thermostat bulb Place the surface thermometer about half way toward the back of the pla...

Страница 9: ...TEM DESCRIPTION PART NUMBER 1 SPARK IGNITION ASSEMBLY SEE Item 4 Figure 6 2 2 THERMOPILE 022770 3 PILOT TUBE 1 4 007998 4 PILOT ASSEMBLY 029769 ALL NATURAL GAS 24 30 029599 LP 24 39 BEF NATURAL GAS OR...

Страница 10: ...the screws 2 Disconnect the wires on the switch and remove switch 3 Snap the new switch into place and reconnect all wires 4 Return the control panel to its normal position THERMOSTAT REMOVAL AND REPL...

Страница 11: ...having a 1 1000MV range Conduct each check below by connecting meter test leads to terminals as indicated All readings are closed circuit A BURNER COIL CHECK A Reading Thermostat contacts CLOSED Gas V...

Страница 12: ...een 75 millivolts and 25 millivolts If dropout occurs outside these limits change the valve WARNING AND OPERATING PLATES All warning and operating plates on the Keating MIRACLEAN Griddle should be in...

Страница 13: ...e to 4 e Gas valve failure e Replace valve Temperature of a Thermostat is not calibrated a Calibrate thermostat with exhaust griddle erratic system running b Air from exhaust hood excessive b Have exh...

Страница 14: ...TY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installation or main...

Страница 15: ...________________________ ADDRESS ______________________________________________________________________________________________________ CITY ___________________________________________________________...

Отзывы: