3

Counter model and floor model fryers 

must be

restrained to prevent tipping

when installed in order

to avoid splashing, spilling, etc. of hot liquid. The
restraining method may be a manner of installation or
by separate means.

LEVELING

The fryer will operate at its highest efficiency when
properly leveled. Place a level on fryer vessel from side
to side. For fryers on legs, the bottom foot of the leg is
adjustable. Turn counter clockwise to decrease height
or clockwise to increase height until level. For fryers on
casters, the casters are adjustable by loosening the
jam nut and turning the caster in or out. When the
desired level is reached, tighten the jam nut.
Adjustments of more than 3/4” are not recommended
on any caster. The same procedure should be followed
to level the fryer from front to back. 

Figure 2-1

RESTRAINING
DEVICES

On fryer installations with casters, casters and jam nuts
must be completely tightened. Adequate means must
also be provided to limit the movement of the appliance
without depending on the connector, the
quick-disconnect device or its associated piping to limit
the appliance movement. 

Connectors must comply with the current ANSI
Z21.69/CAN 1 CAN/CGA 6.16 standard for connectors
for movable gas appliances. Quick-disconnect devices
must comply with the current ANSI Z21.41/CAN 1 6.9
standard for quick-disconnect devices for use with gas
fuel as applicable.

WARNING

IF DISCONNECTION OF THE RESTRAINT IS
NECESSARY, IT MUST BE RECONNECTED WHEN
THE FRYER IS RETURNED TO ITS ORIGINALLY
INSTALLED POSITION.

GAS CONNECTION

WARNING

n

PIPE JOINT COMPOUNDS RESISTANT TO
PROPANE GASES MUST BE USED.

n

BEFORE OPERATING THIS FRYER, CHECK PIPE
JOINTS FOR LEAKS BY USING A SOAP AND
WATER SOLUTION ONLY. DO NOT USE AN
OPEN FLAME!

n

ON AN AA OR CMG (MILLIVOLT) FRYER, DO
NOT SHORT GAS VALVE TERMINALS WHEN
TESTING WIRING AS THERMOSTAT AND GAS
VALVE DAMAGE MAY OCCUR AND CAUSE
UNSAFE CONDITIONS.

Figure 2-3

Main Gas Connection (14TS Model)

FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors and liquids in the
vicinity of this or any other appliance.

You will post, in a prominent location, instructions to be
followed in the event the user smells gas. This
information shall be obtained from your local gas 
supplier. You may use the yellow stick-on label
enclosed on page “i” temporarily until you receive the
data from your local gas supplier.

Connect the fryer to the main gas supply line at the rear
of the fryer. The piping should be a minimum of 3/4”
IPS supply pipe for a single fryer. Batteries require
larger supply lines. Installation must conform with local
codes, or in the absence of local codes, with the
current National Fuel Gas Code ANSI Z223.1/NFPA
54, Natural Gas Installation Code CAN/CGA-B149.1 or
Propane Installation Code CAN/CGA-B149.2.

Содержание INSTANT RECOVERY

Страница 1: ...INSTANT RECOVERY GAS FRYER SERVICE MANUAL KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 715 S 25th AVENUEl BELLWOOD ILLINOIS l 60104 l 1 800 KEATING...

Страница 2: ...nce 9 Oil Breakdown 10 Limited Calibration 10 Thermostat Bulb Positioning 10 11 Hi Limit Check 11 SECTION V SERVICE DIAGNOSIS General 11 Trouble Shooting Charts 12 13 SECTION VI PARTS LIST Ordering Pa...

Страница 3: ...STALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VIC...

Страница 4: ...s l You must maintain the following minimum clearances from combustible and noncombustible construction l You must install this appliance at least 16 inches away from any open flame l Adequate clearan...

Страница 5: ...DEFECTS OR OTHER REPRODUCTIVE HARM II INSTALLATION This fryer MUST be installed inspected calibrated and serviced by qualified and or certified and or licensed service personnel you may void your Keat...

Страница 6: ...rrent ANSI Z21 41 CAN 1 6 9 standard for quick disconnect devices for use with gas fuel as applicable WARNING IF DISCONNECTION OF THE RESTRAINT IS NECESSARY IT MUST BE RECONNECTED WHEN THE FRYER IS RE...

Страница 7: ...NDING PRONG FROM THIS PLUG GAS LEAK TESTING Prior to lighting your fryer 1 Make sure all thermostats switches and safety valves are in the OFF position 2 Turn main On Off manual gas valve to the ON po...

Страница 8: ...gas supply to unit usually at rear by turning handle in line with gas piping or hose Also open manual valve red gas cock on gas piping inside unit where applicable 2 Light the constant pilot located...

Страница 9: ...NG PROCEDURES n USE ONLY KEATING APPROVED BASKETS IN YOUR FRYER NEVER OVERFILL FRY BASKETS DO NOT BANG BASKETS ON BASKET HANGERS OR FRYER VESSEL n CARE SHOULD BE TAKEN WHEN LOWERING BASKETS INTO FRYER...

Страница 10: ...DRAINING WARNING ALWAYS SHUT THE FRYER OFF COMPLETELY BEFORE DRAINING THE FRYER SHOULD BE DRAINED ONLY UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL A DRAIN PIPE AND COVERED CONTAINER SUITABLE F...

Страница 11: ...er to a secure area to prevent accidental spillage 5 Fill fryer vessel to Fill Level line with water WARNING UNDER NO CIRCUMSTANCES SHOULD THE FRYER BE LEFT UNATTENDED DURING BOIL OUT TRAINED PERSONNE...

Страница 12: ...OR The BEEPER will BEEP 4 times If STEP 1 was OK proceed to STEP 2 If not retry Step 1 making sure the power was OFF for at least 30 seconds or more STEP 2 PRESS all 3 buttons in sequence left center...

Страница 13: ...thermostat bulb positioning Keating s patented thermostat application is accurate within 2 F of the dial setting between 250 F 350 F This accuracy is attained only if the thermostat bulb is placed pro...

Страница 14: ...r 14 fryers 6 Refill fryer with oil to fill level line 7 Start fryer preheat and calibrate with thermometer D Hi Limit Check The manual Hi Limit test button can be used to test the Hi Limit Control by...

Страница 15: ...ot b Turn fryer and manual gas valve off orifice s Clean orifice s and pilot tube c Low pilot flame height c Adjust pilot flame height d Flame switch control is faulty d If it takes more than 60 secon...

Страница 16: ...oil d Check with oil supplier for higher grade oil e Fryer is overheating and Hi Limit e Check thermostat calibration control has failed and bulb position See pages 10 11 and replace thermostat if ne...

Страница 17: ...ILOT AIR SHUTTER NIPPLE W NUT 015747 1 1 2 2 2 3 CLIP 004090 1 1 2 2 2 3 7 RUNNER PILOT ORIFICE CALL 1 800 KEATING 1 1 2 2 2 3 8 RUNNER PILOT ORIFICE HOLDER STRAIGHT 004142 1 1 2 2 2 3 9 RUNNER PILOT...

Страница 18: ...15 TS CONTROL PANEL AA CMG CONTROL PANEL BB CONTROL PANEL GAS FRYER ASSEMBLY...

Страница 19: ...16 RUNNER PILOT ASSEMBLY See Page 16 for part numbers...

Страница 20: ...L PLATE 1 030833 3 THERMOSTAT KNOB 1 004163 4 RETAINING SCREWS 3 004610 5 FRY ON OFF SWITCH PLATE 1 007997 6 TOGGLE SWITCH FRY ON OFF 1 004499 7 HI LIMIT TEST PLATE 1 004305 8 HI LIMIT TEST BUTTON 1 0...

Страница 21: ...ITCH MAIN ON OFF BB TS 1 004499 9 HI LIMIT TEST BUTTON BB TS 1 004304 10 TIMER ELECTRONIC TS 2 023709 11 MELT CONTROL BB TS 1 004169 12 NUT WITH BOOT BB TS 1 009389 13 CONTROL PANEL HOODED BB TS 1 14...

Страница 22: ...E SWITCH FRY OFF MELT 1 000521 8 TOGGLE SWITCH MAIN ON OFF 1 004499 9 HI LIMIT TEST BUTTON 1 004304 10 TIMER ELECTRONIC 2 023709 11 MELT CONTROL 1 004169 12 NUT WITH BOOT 1 009389 13 CONTROL PANEL HOO...

Страница 23: ...ITCH BUZZER LIMIT 2 004592 8 MOTOR CCW LEFT Viewing front of fryer 1 000390 9 MOTOR CW RIGHT Viewing front of fryer 1 000391 10 BUZZER ON OFF SWITCH WITH PLATE 1 004499 11 BUZZER 1 004223 12 WIRE HARN...

Страница 24: ...ROD 2 015817 ROLLER PIN 2 016393 ROLLER PIN LOCK 2 016392 5 LIFT ROD FOR SPLIT BASKETS 2 020086 6 BUSHING PUSH ROD 4 016405 7 BUSHING RETAINING RING 4 015831 8 FUSE HOLDER 2 004335 9 FUSE ACTUATOR GRO...

Страница 25: ...the inside of this manual and should be saved for troubleshooting and maintenance The wiring diagrams in this section cover standard fryers which may or may not match the diagrams sent with the fryer...

Страница 26: ...23...

Страница 27: ...24...

Страница 28: ......

Страница 29: ...____________ DEALER ________________________________________________________________________________________________________________ DATE OF PURCHASE __________________________________________________...

Отзывы: