Installed in accordance with all local codes, or in
the absence of local codes, with the current
National Fuel Gas Code Z223.1/NFPA 54, Natural
Gas Installation CAN/CGA-B149.1 or Propane
Installation Code CAN/CGA-B149.2

l

Installed under a properly designed operating
exhaust hood.

l

Connected to the type of gas for which the fryer is
manufactured.

l

Pressure regulator installed in the appliance is
adjusted for the manifold pressure marked on the
serial plate.

l

Adequate air supply to the fryer.

l

In-line pressure regulator, not supplied by Keating,
must be installed outside the appliance (when
needed to maintain the specificied manifold pressure
marked on the serial plate).

l

The equipment is operated in the manner intended
using the proper utensils.

l

Keep the equipment clean and have it checked
periodically.

l

Burner air adjustments, mechanical maintenance
and repairs must be performed by qualified service
personnel.

If the equipment is not installed, operated and
maintained in accordance with the above,
concentrations of carbon monoxide in excess of the
established limits could be present in the kitchen
environment.

ALL PERSONNEL IN THE WORK PLACE WHO MAY
BE SUBJECT TO ANY EXPOSURE OF CARBON
MONOXIDE MUST BE WARNED OF SUCH
POSSIBLE EXPOSURE. THIS WARNING SHOULD
BE CONVEYED IN A MANNER SO THAT IT IS
CLEARLY UNDERSTOOD BY THE EMPLOYEE, AND
THE EMPLOYEE SHOULD BE ASKED IF IN FACT HE
OR SHE UNDERSTANDS THE CORRECT METHOD
OF OPERATION OF THE EQUIPMENT AND THAT A
RISK OF EXPOSURE EXISTS IF THE EQUIPMENT
IS OPERATED IMPROPERLY.

WARNING

IF NOT INSTALLED, OPERATED AND MAINTAINED
IN ACCORDANCE WITH THE MANUFACTURER’S
INSTRUCTIONS, THIS PRODUCT COULD EXPOSE
YOU TO SUBSTANCES IN FUEL OR IN FUEL
COMBUSTION WHICH CAN CAUSE DEATH OR
SERIOUS ILLNESS AND WHICH ARE KNOWN TO
THE STATE OF CALIFORNIA TO CAUSE CANCER,
BIRTH DEFECTS OR OTHER REPRODUCTIVE
HARM.

II INSTALLATION

This fryer MUST be installed, inspected, calibrated and
serviced by qualified and/or certified and/or licensed
service personnel – you may void your Keating
warranty if installation is not completed per current
local, national and Keating specifications. Contact your
dealer for assistance.

DAMAGE DURING
SHIPMENT

The fryer has been assembled, tested and inspected at
the factory. Upon arrival, the complete fryer should be
checked for any damage that may have occurred
during shipment.

The carrier is responsible for all damage in transit
whether visible or concealed. Do not pay for the freight
bill until the fryer has been thoroughly checked for
damage. If concealed damage is found later, contact
the carrier immediately to file a claim.

What to do if equipment arrives damaged:

VISIBLE LOSS OR DAMAGE—Be certain to note this
on the freight or express receipt and have it signed by
the delivery person.

FILE CLAIM FOR DAMAGES IMMEDIATELY –
Regardless of extent of damage.

CONCEALED LOSS OR DAMAGE—If damage is
noticed when equipment is unpacked, notify the freight
company immediately, and file a “concealed damage
claim”. This MUST be done immediately. Be sure to
retain the shipping container for inspection.

Keating does not assume responsibility for Loss OR
Damage incurred in transit.

INSTALLATION

Installation must conform with local codes or, in
absence of local codes, with the current National Fuel
Gas Code Z223.1/NFPA 54, Natural Gas Installation
CAN/CGA–B149.1 or Propane Installation Code
CAN/CGA-B149.2. 

POSITIONING

The fryer must be no closer than 6 inches from any
combustible material and 16 inches away from any
open flame. The fryer must be placed under an exhaust
hood with a fire retardant system. Your ventilation
hood, when installed, must conform to the current
ANSI/NFPA 96 standard. 

ALL

connections and

placement must comply with local and national codes.
It is the responsibility of the owner and local installer to
comply with these regulations when installing the fryer.

Содержание INSTANT RECOVERY

Страница 1: ...INSTANT RECOVERY GAS FRYER SERVICE MANUAL KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 715 S 25th AVENUEl BELLWOOD ILLINOIS l 60104 l 1 800 KEATING...

Страница 2: ...nce 9 Oil Breakdown 10 Limited Calibration 10 Thermostat Bulb Positioning 10 11 Hi Limit Check 11 SECTION V SERVICE DIAGNOSIS General 11 Trouble Shooting Charts 12 13 SECTION VI PARTS LIST Ordering Pa...

Страница 3: ...STALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VIC...

Страница 4: ...s l You must maintain the following minimum clearances from combustible and noncombustible construction l You must install this appliance at least 16 inches away from any open flame l Adequate clearan...

Страница 5: ...DEFECTS OR OTHER REPRODUCTIVE HARM II INSTALLATION This fryer MUST be installed inspected calibrated and serviced by qualified and or certified and or licensed service personnel you may void your Keat...

Страница 6: ...rrent ANSI Z21 41 CAN 1 6 9 standard for quick disconnect devices for use with gas fuel as applicable WARNING IF DISCONNECTION OF THE RESTRAINT IS NECESSARY IT MUST BE RECONNECTED WHEN THE FRYER IS RE...

Страница 7: ...NDING PRONG FROM THIS PLUG GAS LEAK TESTING Prior to lighting your fryer 1 Make sure all thermostats switches and safety valves are in the OFF position 2 Turn main On Off manual gas valve to the ON po...

Страница 8: ...gas supply to unit usually at rear by turning handle in line with gas piping or hose Also open manual valve red gas cock on gas piping inside unit where applicable 2 Light the constant pilot located...

Страница 9: ...NG PROCEDURES n USE ONLY KEATING APPROVED BASKETS IN YOUR FRYER NEVER OVERFILL FRY BASKETS DO NOT BANG BASKETS ON BASKET HANGERS OR FRYER VESSEL n CARE SHOULD BE TAKEN WHEN LOWERING BASKETS INTO FRYER...

Страница 10: ...DRAINING WARNING ALWAYS SHUT THE FRYER OFF COMPLETELY BEFORE DRAINING THE FRYER SHOULD BE DRAINED ONLY UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL A DRAIN PIPE AND COVERED CONTAINER SUITABLE F...

Страница 11: ...er to a secure area to prevent accidental spillage 5 Fill fryer vessel to Fill Level line with water WARNING UNDER NO CIRCUMSTANCES SHOULD THE FRYER BE LEFT UNATTENDED DURING BOIL OUT TRAINED PERSONNE...

Страница 12: ...OR The BEEPER will BEEP 4 times If STEP 1 was OK proceed to STEP 2 If not retry Step 1 making sure the power was OFF for at least 30 seconds or more STEP 2 PRESS all 3 buttons in sequence left center...

Страница 13: ...thermostat bulb positioning Keating s patented thermostat application is accurate within 2 F of the dial setting between 250 F 350 F This accuracy is attained only if the thermostat bulb is placed pro...

Страница 14: ...r 14 fryers 6 Refill fryer with oil to fill level line 7 Start fryer preheat and calibrate with thermometer D Hi Limit Check The manual Hi Limit test button can be used to test the Hi Limit Control by...

Страница 15: ...ot b Turn fryer and manual gas valve off orifice s Clean orifice s and pilot tube c Low pilot flame height c Adjust pilot flame height d Flame switch control is faulty d If it takes more than 60 secon...

Страница 16: ...oil d Check with oil supplier for higher grade oil e Fryer is overheating and Hi Limit e Check thermostat calibration control has failed and bulb position See pages 10 11 and replace thermostat if ne...

Страница 17: ...ILOT AIR SHUTTER NIPPLE W NUT 015747 1 1 2 2 2 3 CLIP 004090 1 1 2 2 2 3 7 RUNNER PILOT ORIFICE CALL 1 800 KEATING 1 1 2 2 2 3 8 RUNNER PILOT ORIFICE HOLDER STRAIGHT 004142 1 1 2 2 2 3 9 RUNNER PILOT...

Страница 18: ...15 TS CONTROL PANEL AA CMG CONTROL PANEL BB CONTROL PANEL GAS FRYER ASSEMBLY...

Страница 19: ...16 RUNNER PILOT ASSEMBLY See Page 16 for part numbers...

Страница 20: ...L PLATE 1 030833 3 THERMOSTAT KNOB 1 004163 4 RETAINING SCREWS 3 004610 5 FRY ON OFF SWITCH PLATE 1 007997 6 TOGGLE SWITCH FRY ON OFF 1 004499 7 HI LIMIT TEST PLATE 1 004305 8 HI LIMIT TEST BUTTON 1 0...

Страница 21: ...ITCH MAIN ON OFF BB TS 1 004499 9 HI LIMIT TEST BUTTON BB TS 1 004304 10 TIMER ELECTRONIC TS 2 023709 11 MELT CONTROL BB TS 1 004169 12 NUT WITH BOOT BB TS 1 009389 13 CONTROL PANEL HOODED BB TS 1 14...

Страница 22: ...E SWITCH FRY OFF MELT 1 000521 8 TOGGLE SWITCH MAIN ON OFF 1 004499 9 HI LIMIT TEST BUTTON 1 004304 10 TIMER ELECTRONIC 2 023709 11 MELT CONTROL 1 004169 12 NUT WITH BOOT 1 009389 13 CONTROL PANEL HOO...

Страница 23: ...ITCH BUZZER LIMIT 2 004592 8 MOTOR CCW LEFT Viewing front of fryer 1 000390 9 MOTOR CW RIGHT Viewing front of fryer 1 000391 10 BUZZER ON OFF SWITCH WITH PLATE 1 004499 11 BUZZER 1 004223 12 WIRE HARN...

Страница 24: ...ROD 2 015817 ROLLER PIN 2 016393 ROLLER PIN LOCK 2 016392 5 LIFT ROD FOR SPLIT BASKETS 2 020086 6 BUSHING PUSH ROD 4 016405 7 BUSHING RETAINING RING 4 015831 8 FUSE HOLDER 2 004335 9 FUSE ACTUATOR GRO...

Страница 25: ...the inside of this manual and should be saved for troubleshooting and maintenance The wiring diagrams in this section cover standard fryers which may or may not match the diagrams sent with the fryer...

Страница 26: ...23...

Страница 27: ...24...

Страница 28: ......

Страница 29: ...____________ DEALER ________________________________________________________________________________________________________________ DATE OF PURCHASE __________________________________________________...

Отзывы: