![background image](http://html2.mh-extra.com/html/keating-of-chicago/gas-fryer/gas-fryer_user-manual_3843549008.webp)
6
SERIES 2000 TS MODELS
OPERATING INSTRUCTIONS
TS CONTROL PANEL – SERIES 2000
START-UP PROCEDURE
WARNING: DO NOT START FRYER WITHOUT
FIRST FILLING FRY POT.
STEP 1. Set "MELT-IDLE-FRY" switch to "IDLE"
position and thermostat to the "OFF"
position.
STEP 2. Turn "MAIN POWER" switch to "ON"
position. Its green light and the timers will
come on.
STEP 3. Light constant pilot located on left side of
pilot runner tube.
STEP 4. Hold the "PUSH TO LIGHT" switch for 30
seconds. The pilot runner tube will light.
STEP 5. Set thermostat to desired temperature.
STEP 6. Set "MELT-IDLE-FRY" switch to "FRY" with
oil in the fry pot. The burners will come on.
Select "MELT" with solid shortening until
liquid shortening is 1" from full mark then
switch to the "FRY" position after packing
shortening around burner tubes.
SHUTDOWN PROCEDURE
STEP 1. Set thermostat to the "OFF" position.
STEP 2. Turn "MAIN POWER" switch to the "OFF"
position. Its green light will go off.
STEP 3. Turn gas supply valve to the "OFF" position.
STEP 4. Check to make sure all burners and pilot are
extinguished.
SERIES 2006 TS MODELS
OPERATING INSTRUCTIONS
TS CONTROL PANEL - SERIES 2006
TS CONTROL PANEL - SERIES 2009
START-UP PROCEDURE
WARNING: DO NOT START FRYER WITHOUT
FIRST FILLING FRY POT.
STEP 1. Set thermostat to the "OFF" position.
STEP 2. Turn "MAIN POWER" switch to "ON"
position. Its green light and the timers will
come on.
STEP 3. Light constant pilot located on left side of
pilot runner tube.
STEP 4. Hold the "PUSH TO LIGHT" switch for 30
seconds. The pilot runner tube will light.
STEP 5. Set thermostat to desired temperature.
STEP 6. Set "MELT-IDLE-FRY" switch to "FRY" with
oil in the fry pot. The burners will come on.
Select "MELT" with solid shortening until
liquid shortening is 1" from full mark then
switch to the "FRY" position after packing
shortening around burner tubes.
SHUTDOWN PROCEDURE
STEP 1. Set thermostat to the "OFF" position.
STEP 2. Turn "MAIN POWER" switch to the "OFF"
position. Its green light will go off.
STEP 3. Turn gas supply valve to the "OFF" position.
STEP 4. Check to make sure all burners and pilot are
extinguished.
SERIES 2009 TS SPARK IGNITION
MODELS OPERATING INSTRUCTIONS
TS SPARK IGNITION CONTROL PANEL SERIES 2006
TS SPARK IGNITION CONTROL PANEL SERIES 2009
START-UP PROCEDURE
WARNING: DO NOT START FRYER WITHOUT
FIRST FILLING FRY POT.
STEP 1. Set thermostat to the "OFF" position.
STEP 2. Turn "MAIN POWER" switch to "ON"
position. Its green light and the timers will
come on.
STEP 3. Set thermostat to desired temperature.
STEP 4. Set "MELT-IDLE-FRY" switch to "FRY" with
oil in the fry pot. The burners will come on.
300
275
A L
OT
C
250
350
D
T
R A
I B
T
HS
E
I F
I
A L
375
325
MELT - FRY
POWER POWER
ON
PILOT
ON
PILOT
T3
T2
S
ET
T1
1-800-
K
EATIN
G
T3
T2
S
ET
T1
1-800-
K
EATIN
G
Содержание GAS FRYER
Страница 20: ...18 SERIES 2000 2005 RUNNER PILOT ASSEMBLY Spark Ignition Models See page 27...
Страница 34: ...32 BB 2000 ELECTRICAL ASSEMBLY AA 2010 ELECTRICAL ASSEMBLY FRONT DRAIN...
Страница 36: ...34 BB 2006 ELECTRICAL ASSEMBLY WITH SAFE EASY FILTER 34 X 24 BB 2007 ELECTRICAL ASSEMBLY FRONT DRAIN...
Страница 39: ...37 TS 2007 ELECTRICAL ASSEMBLY FRONT DRAIN TS 2000 ELECTRICAL ASSEMBLY WITH SAFE EASY FILTER...
Страница 40: ...38 TS 2007 ELECTRICAL ASSEMBLY BASKET LIFT FRONT DRAIN TS 2007 ELECTRICAL ASSEMBLY WITH SAFE EASY FILTER...
Страница 41: ...39 TS 2007 ELECTRICAL ASSEMBLY SPARK IGNITION FRONT DRAIN TS 2009 ELECTRICAL ASSEMBLY BASKET LIFT FRONT DRAIN...
Страница 43: ...41 34 X 24 TS 2007 ELECTRICAL ASSEMBLY FRONT DRAIN 34 X 24 TS 2007 ELECTRICAL ASSEMBLY FRONT DRAIN...
Страница 46: ...44 CPU 2007 ELECTRICAL ASSEMBLY WITH SAFE EASY FILTER CPU 2007 ELECTRICAL ASSEMBLY FRONT DRAIN...
Страница 49: ...47 BASKET LIFT ELECTRICAL ASSEMBLY WITH CPU MODELS SERIES 2007...
Страница 50: ......
Страница 51: ......