-13-
Key Operation
F1 (Program)
:
Access to Program Mode to make a change for the currently running program.
Changes are effective from the next STEP. You cannot change the STEP that is in
progress. The changes are reflected in the only operation in progress, it will not be
saved in the storage data.
F2 (Graph)
:
Switch page to STEP1
~
10 to the STEP graph display.
F3 (Graph)
:
Switch page to STEP11
~
20 to the STEP graph display.
F4 (Pass)
:
Pass running STEP. It is enabled when you press for about 1 second.
Start/Stop
:
Stops the firing and return to standby mode. It is enabled when you press for about
1 second.
Editing of Running Program
1. Go to Program Mode.
2. Press [F1] key while pressing the
▲
key.
3. Use
▲▼
keys to adjust the program.
4. Press [F2] key (OK) to return to Program Mode.
Press the [OK] key to go to Stand-by mode.
If set to a range of 1
~
100
℃
the temperature of the final STEP, table does not
decrease while the top-level firing at the end. Please set If you do not want to lower
the firing table at the end of firing for the safety.
If temprature of the Final STEP is between 1
~
100°C, the firing table does not go
down and stays at the highest position (0). If necessary for safety purpose, please
program temperature of the final STEP to less than 100°C.