KBR multimess D9-PQ
20144 EDEBD
A0228-5023-1_EN
15
Storage of measured values
Internal memory
1024 MB
SD memory card
1 GByte to 32 GByte
Binary inputs (BI)
Range
148...250 VAC(/DC)
- H – Level
- L – Level
> 35 V
< 20 V
Signal frequency
DC ... 70 Hz
Input resistance
> 100kΩ
Electrical isolation
Optocoupler,
electrically isolated
Electrical safety
DIN EN 61010
300V CAT II
Binary outputs (BO)
Contact specification
(EN60947-4-1, -5-1) :
Configuration
Rated voltage
Rated current
Rated load AC1
Rated load AC15, 230VAC
Breaking capacity DC1,
30/110/220 V
SPDT
250VAC
6A
1500VA
300VA
6/0.2/0.12A
No. of switching
operations AC1
≥ 60•103 electrical
Electrical isolation
Isolated from all
internally potentials
Electrical safety
DIN EN 61010
300V CAT II
Power supply
Feature
H1
H2
AC
90...264 V -
DC
100...300 V 18...72 V
Power
consumption.
≤ 10 W
< 20VA
≤ 10 Watt
Frequency
40...70Hz
-
External fuse
characteristics
6A
B
6A
B