ROPES - INSPECTION AND MAINTENANCE
⇒
Check the ropes of the canopy drive. Should
individual wires be frayed, replace the rope
immediately.
㉟
Grease the rope in the area of the return pulley
with copper crease or adhesive lubricant
HHS-2000 (KBL 1200024000).
SPRINGS - INSPECTION
Do a visual inspection.
Look for damage in the area around the hook
eyes of the canopy springs.
INSTALL SPRINGS AND ROPES
㊴
Install rope with cantilever beam and adjust
to the measured value
㊳
.
Caution: lock adjusting screw
㊶
.
Repeat on the other side.
㉞
Lift the canopy and secure with the two
securing bolts.
⇒
Install both springs.
㊱
Preload springs one after the other on both
sides with a pipe wrench SW19.
㊷
㊷
Set both springs to the position given accord-
ing to factory settings (sticker, device feets).
㉞
Remove both securing bolts.
FINE ADJUSTMENT OF THE CANOPY DRIVE
⇒
Test the canopy drive unit. The canopy should
stop in all positions. If this is not the case,
the tension of the springs must be adjusted
evenly on both sides.
Ventilation and air-conditioning
↵
In order to preserve the performance of the air-con-
ditioning unit, clean the heat exchangers after
500 - 600 hours of operation.
㊸
㊺
㊹
Air
conditioning
unit
㊸
Heat exchanger
㊹
Condensate pump
㊹
Condensate tray
⇒
Open the bench part.
㊸
Clean the heat exchanger.
Vacuum it carefully, paying attention not to