Filter panes
4
4
↵
DANGER
Excessive UV radiation
Operating the tanning device with defective filter
panes can result in serious injury to skin and eyes.
• Never operate the tanning device if the filter pane is
not present or defective.
• Carry out regular visual inspections.
• Replace filter panes only with ones of the same
type.
• Have the filter panes installed only by trained
technical personnel.
REMOVING THE FILTER PANES (PREPARATION)
⑩
⑪
⑪
⑫
⑫
⇒
Tilt the canopy pane down.
⇒
Tilt the side pane down.
⑩
Undo the screws of the mirror panels (6 x M5).
⑪
Remove the central panels.
⑫
Tilt up the outer panels.
REMOVING THE FILTER PANES
⑭
⑬
⑬
The pane is fixed with two clamps each on
the two longitudinal edges.
⑭
Remove the pane from the spring retainer.
To do so, press the pane to be exchanged
slightly against a pair of clamps and, while
keeping it slightly pressed, tilt it out of the
holder on the relieved side.
The filter pane of the side part is replaced analogously
to the procedure described for the canopy
⑬ ⑭
.
Difference:
• Use an angled hexagon socket spanner (4 mm) in
order to undo the screw of the mirror panel
⑩
.
SAFETY FUNCTION
The facial tanners are equipped with an additional
safety function. There is a protective pane-switch
behind each filter pane. This switch turns off the
tanner if the filter pane is missing or broken.