A s s e m b l y I n s t r u c t i o n s
|
6808 /7908
16
4.6.2 REMOVE AQUACOOL UNIT
• Loosen the cable harness (D10/D11) on the left
foot and pull it out of the opening.
• Put it in front of the electronic box together with the
condensate canister
⑭
.
⑭
• Loosen all wires and the plug (X8) of the aquaCool
unit. Transport the unit to the installation site.
4.6.3 REMOVE ELECTRONIC BOX
• Disconnect all connectors routed in the rear wall on
the left-hand side of the electronic box.
• Follow the connection diagram on the
left-hand side of the electronic box
during installation!