7. MAINTENANCE

Check the connection between power supply plug and socket 

and ground wiring regularly;

In some cold area (below 0

), if the system will be stopped for 

a long time, all the water should be released in case of freezing 

of inner tank and damage of E-heater.

It is recommended to clean the inner tank and E-heater every 

half year to keep an efficient performance.

Check the anode rod every half year and change it, if it has 

been used out. For more details, please contact the supplier or 

the after-sale service.

It is recommended to set a lower temperature to decrease the 

heat release, prevent scale and save energy if the outlet water 

volume is sufficient.

Clean the air filter every month in case of any inefficiency on the 

heating performance.

In terms of the filter set in air inlet directly (namely, air inlet 

without connect with duct), the method of dismantle the filter is: 

anti-clockwise unscrew the air inlet ring, take out the filter and 

clean it completely, finally, remount it to the unit.

Before shutting the system off for a long time, please:

Shut off the power supply;

Release all the water in water tank and the pipeline and close 

all the valves;

Check the inner components regularly.

7.2   Recommended regular maintenance table

7.1   Maintenance

8)

Turn off the power, and turn off the water inlet valve.

Open hot water tap, and decrease the pressure of the inner 

container.

How to change the anode rod 

Checking

Item

Checking

content

Checking frequency

Action

1

air filter

(inlet/outlet)

every month

Clean the filter

2

anode rod

every half year

Replace it if it has

been used out

3

inner tank

every half year

Clean the tank

4

5

E-heater

every half year

Clean E-heater

Operate the 

hander of PTR 

valve to ensure 

that waterways 

are clear.

PTR valve

If water doesn't flow freely when operating the 

hander, replace PTR valve with a new one.

every year

1. Battery must be disposed of properly. Do

not short circuit or dispose of in the fire.

2. Keep batteries out of the reach of children.

3. Caution for ingestion.

4. Non-rechargeable batteries are not to be

recharged.

5. Exhausted batteries are to be removed

from the product.

6. Dispose of the old batteries in the special

containers to be found in the sales outlets.

7. Replace the battery must contact the

supplier or the after-sale service.

WARNING

CAUTION

The maintenance of the unit requires 

professional after-sales personnel responsible 

for overhauling the unit.

    MD23IU-003AW

Содержание KTHR-190

Страница 1: ...roduct Before using your unit please read this manual carefully and keep it for future reference If you need to consult the electronic manual please go to this website https www kaysun es INSTALLATION...

Страница 2: ......

Страница 3: ...ent device RCD with the rating not exceeding 30mA shall be incorporated in the fixed wiring according to the national rule The handle of PTR valve should be pulled out once per half a year to make sur...

Страница 4: ...pressure relief device is to be operated regularly to remove lime deposits and to verify that it is not blocked NOTE All the picture in this manual are for explanation purpose only They may be slight...

Страница 5: ...E Above calculation is based on the ideal condition the final cost bill will be different caused by the actual running conditions such as running period ambient temperature etc 1 SAFETY INFORMATION Pl...

Страница 6: ...hildren For appliances which contain button or non lithium batteries The battery can cause serious injuries if it is swallowed or placed inside any part of the body If you think batteries might have s...

Страница 7: ...off or pull out the power plug Otherwise an electric shock and injury may be caused Water temperature over 50 can cause severe burns instantly from scalds Children disabled and elderly are at highest...

Страница 8: ...to the outdoor unit s instruction manual The unit should be located in an area not subject to freezing temperatures The unit located in unconditioned spaces i e garag es basements etc may require the...

Страница 9: ...ease ensure the vertical and reliable installation of the tank and the necessary space for installation and maintenance Fixing method WARNING The appearance of the water tank and the orientation of th...

Страница 10: ...installed in inclosed space The water heater must be located in a space 15m and must have unrestricted air flow As an example a room that has an 2 5 tall ceiling and is 3 meters long by 2 meters wide...

Страница 11: ...he One Way Valve thread in accessories is RC3 4 It is used to prevent water from flowing backwards After water system piping work turn on the cold water inlet valve and hot water outlet valve and star...

Страница 12: ...arge amount 1 84kg there are no additional minimum floor area requirements In case of total refrigerant amount 1 84 kg the unit should be installed operated and stored in a room with a floor area larg...

Страница 13: ...Cord mm2 Manual Switch A Capcity Fuse A Model Name Power Supply Min Diameter of Power Supply Cord mm2 220 240V 50Hz KTHR 190 1 5 For water tank with electric heating 1 5 For water tank with electric...

Страница 14: ...e properly installed with a discharge pipe run to an adequate drain and sheltered from freezing All piping properly installed and free of leaks Unit completely filled with water Water temperature limi...

Страница 15: ...ficient inlet water pressure between0 15MPa and 0 65MPa 4 2 1 Checking list before commisionning Emptying Drainpipe shut off valve Close After emptying please replace the nut of drainpipe Close Open D...

Страница 16: ...the switch is closed the unit will be stopped forcibly If switch breaks the unit can run normally according settings No Hour low bit Min high bit Min Low bit unit Explenation 12 13 14 8 9 10 11 7 TP...

Страница 17: ...lock Whenever there is any setting for clock There are daily or weekly TIMER icon If anyone of them has been set this icon will lighten the corresponding one when screen is unlocked If there is none o...

Страница 18: ...as been running for a long time without reaching the set Temp 10 11 12 Error It will be lightened when unit is under protection error VACATION MODE For the outgoing vacation mode the water tank is set...

Страница 19: ...s the TIMER button to the day timer icon press the confirmation button to enter the day timer setting interface the day timer has a total of 6 time periods each time period can be set to open the time...

Страница 20: ...tion of the up down button or pressing the return button or the power on off button you can directly exit the date and time setting 3 Setting can be done in both power on and power off state Child loc...

Страница 21: ...es 3 The 2 4GHz preferable or 5GHz band wireless signal is enabled on your wireless router Android Phone users scan Android QR code or go to google play search Nethome Plus App and download it IOS use...

Страница 22: ...US SK106 EU SK106 FCC ID 2ADQOMDNA22 IC 12575A MDNA22 US SK109 EU SK109 EU SK110 US SK110 FCC ID 2ADQOMDNA23 IC 12575A MDNA23 In Canada CAN ICES 3 B NMB 3 B Le pr sent appareil est conforme aux CNR I...

Страница 23: ...eration on panel for 1 min unit will lock the panel shows to unlock the panel please press the button for 2 seconds Q Why sometimes there is some water flowed from drainage pipe of PTR valve A Because...

Страница 24: ...nnot be started within 3 minutes of stopping The water heater cannot run for about 3 minutes after running stops when the power switch is turned on The water temperature is displayed as dropping Low a...

Страница 25: ...nk setting operation mode the tank energy saving mode host heating hot water to the maximum water temperature will stop working using electric heating heating check whether the electric heating is wor...

Страница 26: ...flow out Get off the anode rod Replace with a new one and make sure effective sealed Open cold water inlet tap untill water flows out from outlet tap then turn of water outlet tap Power on then resta...

Страница 27: ...in water tank and the pipeline and close all the valves Check the inner components regularly 7 2 Recommended regular maintenance table 7 1 Maintenance 8 Turn off the power and turn off the water inlet...

Страница 28: ......

Отзывы: