4.1 Water affusion before operation

4. TRIAL-RUNNING

Water Affusion

Hot water outlet

Close

Water out

When water flows out from the water outlet, 

 the tank is full. Turn off the hot water outlet

 valve and water affusion is finished.

Open

Open the cold water inlet valve and the hot 

water outlet valve.

Cold water inlet

 Hot water outlet

Open

Before using this unit, please follow the steps below.

Water Affusion: If the unit is used for the first time or used again after 

emptying the tank, please make sure that the tank is full of water 

before turning on the power.

Running Temperature Range

Setting water temperature target range: 38~70ºC.

Electrical heater running ambient temperature range: -20~47ºC.

Water temperature limits:

4.2 Trial- running

Checking list before trial-running.
Correct installation of the system.
Correct connection of  water/air piping and wiring.
Condensate draining smoothly well insulation work for all 

hydraulic part.
Correct power supply.
No air in the water pipeline and all valves opened.
Effective electric leakage protector installation.
Sufficient inlet water pressure (between0.15MPa and 0.65MPa).

4.2.1 Checking list before commisionning. 

Emptying

Drainpipe shut-off valve

Close

After emptying, please replace the nut of 

drainpipe.

Close

Open

Drainpipe shut-off valve

Open

Cold water inlet

Close the cold water inlet valve, open the hot 

water outlet valve and open drainpipe. 

 Hot water outlet

CAUTION

After powered on, the display lights up. 

Users can operate the unit through the 

buttons under the display.

Emptying: If the unit needs cleaning, moving 

etc, the tank should be emptied.

Operation without water 

in water tank may result 

in the damage of auxiliary 

E-heater. Due to such

damage, manufacturer 

will not be liable for any 

damages caused by 

this issue.

1)
2)
3)
4)

5)
6)
7)
8)

Heat source will be automatically selected by unit. But manually 

E-Heater operation is available.

3)

System Structure Figure

Unit has two kinds of heat sources: heat pump(compressor) 

and electric heater.

Unit will automatically select heat sources to heat water to the 

target temperature.

Water Temperature Display

The temperature shown on the display depends on the maximum 

of

 

 the upper sensor and the lower sensor. 

4.2.2 About Running

1)

2)

    Tank

Temperature sensor(T5U)

Electric heater

Water inlet

Water outlet

Temperature sensor(T5L)

13

Содержание KTHR-190

Страница 1: ...roduct Before using your unit please read this manual carefully and keep it for future reference If you need to consult the electronic manual please go to this website https www kaysun es INSTALLATION...

Страница 2: ......

Страница 3: ...ent device RCD with the rating not exceeding 30mA shall be incorporated in the fixed wiring according to the national rule The handle of PTR valve should be pulled out once per half a year to make sur...

Страница 4: ...pressure relief device is to be operated regularly to remove lime deposits and to verify that it is not blocked NOTE All the picture in this manual are for explanation purpose only They may be slight...

Страница 5: ...E Above calculation is based on the ideal condition the final cost bill will be different caused by the actual running conditions such as running period ambient temperature etc 1 SAFETY INFORMATION Pl...

Страница 6: ...hildren For appliances which contain button or non lithium batteries The battery can cause serious injuries if it is swallowed or placed inside any part of the body If you think batteries might have s...

Страница 7: ...off or pull out the power plug Otherwise an electric shock and injury may be caused Water temperature over 50 can cause severe burns instantly from scalds Children disabled and elderly are at highest...

Страница 8: ...to the outdoor unit s instruction manual The unit should be located in an area not subject to freezing temperatures The unit located in unconditioned spaces i e garag es basements etc may require the...

Страница 9: ...ease ensure the vertical and reliable installation of the tank and the necessary space for installation and maintenance Fixing method WARNING The appearance of the water tank and the orientation of th...

Страница 10: ...installed in inclosed space The water heater must be located in a space 15m and must have unrestricted air flow As an example a room that has an 2 5 tall ceiling and is 3 meters long by 2 meters wide...

Страница 11: ...he One Way Valve thread in accessories is RC3 4 It is used to prevent water from flowing backwards After water system piping work turn on the cold water inlet valve and hot water outlet valve and star...

Страница 12: ...arge amount 1 84kg there are no additional minimum floor area requirements In case of total refrigerant amount 1 84 kg the unit should be installed operated and stored in a room with a floor area larg...

Страница 13: ...Cord mm2 Manual Switch A Capcity Fuse A Model Name Power Supply Min Diameter of Power Supply Cord mm2 220 240V 50Hz KTHR 190 1 5 For water tank with electric heating 1 5 For water tank with electric...

Страница 14: ...e properly installed with a discharge pipe run to an adequate drain and sheltered from freezing All piping properly installed and free of leaks Unit completely filled with water Water temperature limi...

Страница 15: ...ficient inlet water pressure between0 15MPa and 0 65MPa 4 2 1 Checking list before commisionning Emptying Drainpipe shut off valve Close After emptying please replace the nut of drainpipe Close Open D...

Страница 16: ...the switch is closed the unit will be stopped forcibly If switch breaks the unit can run normally according settings No Hour low bit Min high bit Min Low bit unit Explenation 12 13 14 8 9 10 11 7 TP...

Страница 17: ...lock Whenever there is any setting for clock There are daily or weekly TIMER icon If anyone of them has been set this icon will lighten the corresponding one when screen is unlocked If there is none o...

Страница 18: ...as been running for a long time without reaching the set Temp 10 11 12 Error It will be lightened when unit is under protection error VACATION MODE For the outgoing vacation mode the water tank is set...

Страница 19: ...s the TIMER button to the day timer icon press the confirmation button to enter the day timer setting interface the day timer has a total of 6 time periods each time period can be set to open the time...

Страница 20: ...tion of the up down button or pressing the return button or the power on off button you can directly exit the date and time setting 3 Setting can be done in both power on and power off state Child loc...

Страница 21: ...es 3 The 2 4GHz preferable or 5GHz band wireless signal is enabled on your wireless router Android Phone users scan Android QR code or go to google play search Nethome Plus App and download it IOS use...

Страница 22: ...US SK106 EU SK106 FCC ID 2ADQOMDNA22 IC 12575A MDNA22 US SK109 EU SK109 EU SK110 US SK110 FCC ID 2ADQOMDNA23 IC 12575A MDNA23 In Canada CAN ICES 3 B NMB 3 B Le pr sent appareil est conforme aux CNR I...

Страница 23: ...eration on panel for 1 min unit will lock the panel shows to unlock the panel please press the button for 2 seconds Q Why sometimes there is some water flowed from drainage pipe of PTR valve A Because...

Страница 24: ...nnot be started within 3 minutes of stopping The water heater cannot run for about 3 minutes after running stops when the power switch is turned on The water temperature is displayed as dropping Low a...

Страница 25: ...nk setting operation mode the tank energy saving mode host heating hot water to the maximum water temperature will stop working using electric heating heating check whether the electric heating is wor...

Страница 26: ...flow out Get off the anode rod Replace with a new one and make sure effective sealed Open cold water inlet tap untill water flows out from outlet tap then turn of water outlet tap Power on then resta...

Страница 27: ...in water tank and the pipeline and close all the valves Check the inner components regularly 7 2 Recommended regular maintenance table 7 1 Maintenance 8 Turn off the power and turn off the water inlet...