Kaysun KTHR-190 Скачать руководство пользователя страница 18

16

No.

Icon

Description

 1

 2

Default HYBRID mode 

Switch to E-heater mode

Switch to ECONOMY mode

Switch to VACATION mode

Adjust vacation days (1-360 days)

Switch to smart mode

Switch to HYBRID mode

Use this key to switch mode 

 16

 17

 18

When any key is invalid, this icon will flash 3 sec.

 The icon lights up when the water temperature is 

 being set.

 The icon lights up when the clock is being set.

 20

When the heat pump is operating and producing hot 

water, the icon lights up.

 21

When the SG signal is invalid, this icon does not light 

up and the machine does not switch on normally.

 19

Wireless:

       

will be lightened when Wireless is connected; 

       

will be extinguished when Wireless is not 

connected;

       

will flash with 2Hz frequency when setting 

Wireless.

HEAT PUMP ICON:

Smart Grid ICON:

This key is used to cancel all settings 

and exit the setting state. When Wireless 

connection is normal, long press the 

Cancel button for more than 8s to exit 

Wireless connection. 

Icon          will light up.  then the unit will 

heat up water to 70

 at least for 

disinfection.  

Click the button to turn on the forced sterilization 

function.

NOTE: When the operating conditions are not met 

to turn on this function, the corresponding icon on 

the wire controller lights up briefly and then goes 

out.

When the machine is disinfected

press 

this button to cancel it

.

 then the         will  

be extinguished

.

HYBRID MODE:

Operating in heat pump mode, the electric heater and

heat pump will heat up together when in extremely low

ambient temperatures or when the heat pump has been

running for a long time without reaching the set Temp.

 10

 11

 12

Error:

It will be lightened 

when unit is under protection/error

.

VACATION MODE:

For the outgoing vacation mode, the water tank is set

at 15°C. Maintains low tank water temperature,

preheats hot water and anti-freeze lines, while

reducing on/off operation of the tank.

 13

 14

E-HEAT MODE:

Operate in accordance with the heat pump mode, the

heat pump outdoor unit and the electric heater running

at the same time.

ECONOMY MODE:

In accordance with the heat pump mode of operation,

the heat pump external unit heats up to the maximum

water temperature before turning on the electric

auxiliary heater for heating, the heat pump and the

electric auxiliary heater will not be turned on at the

same time.

Factory default mode setting, it is recommended to set

this mode to run when heat recovery COOL+DHW.

 15

SMART MODE:

Records the hot water usage habits of users over the

past 7 days and turns on the heating in advance

according to the user's peak water usage hours. All

other unconventional hot water hours are in standby

mode, without heating operation (it is recommended

that users set this mode after 7 days of regular and

normal operation of the water heater to avoid affecting

the normal use of the water heater by failing to record

the complete user habits.)

SMART

Any pressing of button is effective only under button and display 

unlocked state.

7

8

6

It is recommended to use this mode of operation when

making hot water alone, which is more energy-saving.

NOTE:

 Energy-saving mode to limit the start of 

electric heating, running more energy-saving, but do 

not recommend COOL + DHW use this mode, easy 

to affect the effect of hot water heating effect.

Содержание KTHR-190

Страница 1: ...roduct Before using your unit please read this manual carefully and keep it for future reference If you need to consult the electronic manual please go to this website https www kaysun es INSTALLATION...

Страница 2: ......

Страница 3: ...ent device RCD with the rating not exceeding 30mA shall be incorporated in the fixed wiring according to the national rule The handle of PTR valve should be pulled out once per half a year to make sur...

Страница 4: ...pressure relief device is to be operated regularly to remove lime deposits and to verify that it is not blocked NOTE All the picture in this manual are for explanation purpose only They may be slight...

Страница 5: ...E Above calculation is based on the ideal condition the final cost bill will be different caused by the actual running conditions such as running period ambient temperature etc 1 SAFETY INFORMATION Pl...

Страница 6: ...hildren For appliances which contain button or non lithium batteries The battery can cause serious injuries if it is swallowed or placed inside any part of the body If you think batteries might have s...

Страница 7: ...off or pull out the power plug Otherwise an electric shock and injury may be caused Water temperature over 50 can cause severe burns instantly from scalds Children disabled and elderly are at highest...

Страница 8: ...to the outdoor unit s instruction manual The unit should be located in an area not subject to freezing temperatures The unit located in unconditioned spaces i e garag es basements etc may require the...

Страница 9: ...ease ensure the vertical and reliable installation of the tank and the necessary space for installation and maintenance Fixing method WARNING The appearance of the water tank and the orientation of th...

Страница 10: ...installed in inclosed space The water heater must be located in a space 15m and must have unrestricted air flow As an example a room that has an 2 5 tall ceiling and is 3 meters long by 2 meters wide...

Страница 11: ...he One Way Valve thread in accessories is RC3 4 It is used to prevent water from flowing backwards After water system piping work turn on the cold water inlet valve and hot water outlet valve and star...

Страница 12: ...arge amount 1 84kg there are no additional minimum floor area requirements In case of total refrigerant amount 1 84 kg the unit should be installed operated and stored in a room with a floor area larg...

Страница 13: ...Cord mm2 Manual Switch A Capcity Fuse A Model Name Power Supply Min Diameter of Power Supply Cord mm2 220 240V 50Hz KTHR 190 1 5 For water tank with electric heating 1 5 For water tank with electric...

Страница 14: ...e properly installed with a discharge pipe run to an adequate drain and sheltered from freezing All piping properly installed and free of leaks Unit completely filled with water Water temperature limi...

Страница 15: ...ficient inlet water pressure between0 15MPa and 0 65MPa 4 2 1 Checking list before commisionning Emptying Drainpipe shut off valve Close After emptying please replace the nut of drainpipe Close Open D...

Страница 16: ...the switch is closed the unit will be stopped forcibly If switch breaks the unit can run normally according settings No Hour low bit Min high bit Min Low bit unit Explenation 12 13 14 8 9 10 11 7 TP...

Страница 17: ...lock Whenever there is any setting for clock There are daily or weekly TIMER icon If anyone of them has been set this icon will lighten the corresponding one when screen is unlocked If there is none o...

Страница 18: ...as been running for a long time without reaching the set Temp 10 11 12 Error It will be lightened when unit is under protection error VACATION MODE For the outgoing vacation mode the water tank is set...

Страница 19: ...s the TIMER button to the day timer icon press the confirmation button to enter the day timer setting interface the day timer has a total of 6 time periods each time period can be set to open the time...

Страница 20: ...tion of the up down button or pressing the return button or the power on off button you can directly exit the date and time setting 3 Setting can be done in both power on and power off state Child loc...

Страница 21: ...es 3 The 2 4GHz preferable or 5GHz band wireless signal is enabled on your wireless router Android Phone users scan Android QR code or go to google play search Nethome Plus App and download it IOS use...

Страница 22: ...US SK106 EU SK106 FCC ID 2ADQOMDNA22 IC 12575A MDNA22 US SK109 EU SK109 EU SK110 US SK110 FCC ID 2ADQOMDNA23 IC 12575A MDNA23 In Canada CAN ICES 3 B NMB 3 B Le pr sent appareil est conforme aux CNR I...

Страница 23: ...eration on panel for 1 min unit will lock the panel shows to unlock the panel please press the button for 2 seconds Q Why sometimes there is some water flowed from drainage pipe of PTR valve A Because...

Страница 24: ...nnot be started within 3 minutes of stopping The water heater cannot run for about 3 minutes after running stops when the power switch is turned on The water temperature is displayed as dropping Low a...

Страница 25: ...nk setting operation mode the tank energy saving mode host heating hot water to the maximum water temperature will stop working using electric heating heating check whether the electric heating is wor...

Страница 26: ...flow out Get off the anode rod Replace with a new one and make sure effective sealed Open cold water inlet tap untill water flows out from outlet tap then turn of water outlet tap Power on then resta...

Страница 27: ...in water tank and the pipeline and close all the valves Check the inner components regularly 7 2 Recommended regular maintenance table 7 1 Maintenance 8 Turn off the power and turn off the water inlet...