Kaysun KTHR-190 Скачать руководство пользователя страница 19

INCREASE AND DECREASE

If screen is unlocked, corresponding value will 

increase by pressing the button.

● When setting temperature, press more than 1s,

temperature value will be increased continuously;

● When setting clock/timer, press more than 1s,

clock/timer value will be increased continuously;

● When setting vacation days, press more than 1s,

day value will be increased continuously;

On querying, check items will page up by pressing it

.

17

Engineering Mode

1) In the main interface, press and hold the copy key
for 3 seconds to enter the engineering mode; use 
the up and down keys to switch the inspection 
channel, and the attribute value of the channel will 
be displayed when switching to the channel. By up 
and down key, you can modify a parameter setting, 
after setting and adjusting, press confirm key to 
return to the main interface to make the setting 
effective (channel 2, 3, 4, 34, 35 will be effective 
immediately). Press the Return button to return to 
the previous interface (channel selection interface). 
After 30 seconds from the last operation of the up 
and down buttons, or by pressing the return button 
or the on/off button, you can directly exit the 
engineering mode.
2

Engineering mode can be accessed in both

power-on and power-off state.

F13 - Priority settings for Heating (AC) and Hot 

water production (DHW)

Parameter 0: Air conditioning is prioritized;
Parameter 1: Hot water priority;
The factory default setting is air conditioning priority, 
during engineering installation, it is necessary to 
confirm its priority selection settings with the 
customer and guide the instructions for use.
It is strictly prohibited for the customer to change the 
parameter settings of other channels in the 
engineering mode without authorisation to avoid 
affecting the normal operation of the unit or causing 
damage to the prototype.

Power on/off button

Press the button to turn the device on or off.

No

Icon

Description

 5

 6

 3

 4

No

Icon

Description

 7

 8

CONFIRM

Press it to upload setting parameters after setting 

any parameter.

TIMER (Daily setting)

TIMER (Weekly setting)

Checking function

1) In the main interface, press and hold the search
key for 1 second to enter the spot check function,
and use the up and down keys to switch the spot
check channel, and the attribute value of the
channel will be displayed when switching to the
channel, and the specific channel can be found in
the function book.
2) After 30 seconds from the last operation of the up
and down keys, or by pressing the return key or the
on/off key, you can directly exit the engineering
mode;
3

Query mode can be entered in both power-on

and power-off state.

1) Press the TIMER         button to the day timer icon          ,
    press the confirmation button         to enter the day timer
    setting interface, the day timer has a total of 6 time
    periods, each time period can be set to open the time,
    close the time, mode, set the temperature of the water;
    when set the first time period set the temperature of the
    water, press the confirmation button to enter the next
    time period of the set; when set the sixth time period set
    the temperature of the water, press the confirmation
    button to return to the main interface; during this period,
    you can press the return button          Return to the
    previous setting or main interface;
2) When setting the on time and off time, press the delete
    button       , the time can be restored to the default value,
    and displaying ( -. --).
3) If there is a conflict between the set time periods, the

time period set at the back will be the valid time period,
and the time period in front will be the invalid time period;
the invalid time period restores the default setting

4) You can enter the daily timer setting in both power-on

and power-off state.

1) Press the TIMER button to the weekly timer icon            , 

press the confirmation button        to enter the weekly
timer setting interface, weekly timer a total of 7 days,
there are 6 time slots can be set each day, each time
slot can be set to open the time, close the time, the
mode, set the water temperature; when the first time
slot set the water temperature, press the confirmation
button to enter the next time slot settings; when the
sixth time slot set the temperature, press the confirma-

    tion button to return to weekly After setting the water
    temperature for the 6th period, press the confirmation
    key to return to the selection of week; during this period,
    you can press the return key to return to the previous
    level of setting or the main interface;
2) When setting the on time and off time, press the delete

button         to restore the time, mode and set water
temperature to the default value, and displaying (-. --).

3) If you adjust the timing time again after the setting is

completed, then all the settings after the adjustment
time period will be canceled. For example, if you adjust
the timer on for time period 2, the timer off for time
period 2, and the settings for time periods 3, 4, 5, and 6
will all be canceled to (-:---) after adjustment. Mode and
setting water temperature become default values
(Energy saving mode, 60

ć

)

4) In the weekly timer setting, in the weekly selection,

use the copy button       , you can locate the setting of a
certain day to the base day, select other days, press the
copy button to change the status of the day, the fast
flashing is selected, the slow flashing is unselected, and
after pressing on the confirmation button, you can copy
the setting of the base day to the selected day;

5) You can enter the weekly timer setting in both power-on

and power-off state.

Содержание KTHR-190

Страница 1: ...roduct Before using your unit please read this manual carefully and keep it for future reference If you need to consult the electronic manual please go to this website https www kaysun es INSTALLATION...

Страница 2: ......

Страница 3: ...ent device RCD with the rating not exceeding 30mA shall be incorporated in the fixed wiring according to the national rule The handle of PTR valve should be pulled out once per half a year to make sur...

Страница 4: ...pressure relief device is to be operated regularly to remove lime deposits and to verify that it is not blocked NOTE All the picture in this manual are for explanation purpose only They may be slight...

Страница 5: ...E Above calculation is based on the ideal condition the final cost bill will be different caused by the actual running conditions such as running period ambient temperature etc 1 SAFETY INFORMATION Pl...

Страница 6: ...hildren For appliances which contain button or non lithium batteries The battery can cause serious injuries if it is swallowed or placed inside any part of the body If you think batteries might have s...

Страница 7: ...off or pull out the power plug Otherwise an electric shock and injury may be caused Water temperature over 50 can cause severe burns instantly from scalds Children disabled and elderly are at highest...

Страница 8: ...to the outdoor unit s instruction manual The unit should be located in an area not subject to freezing temperatures The unit located in unconditioned spaces i e garag es basements etc may require the...

Страница 9: ...ease ensure the vertical and reliable installation of the tank and the necessary space for installation and maintenance Fixing method WARNING The appearance of the water tank and the orientation of th...

Страница 10: ...installed in inclosed space The water heater must be located in a space 15m and must have unrestricted air flow As an example a room that has an 2 5 tall ceiling and is 3 meters long by 2 meters wide...

Страница 11: ...he One Way Valve thread in accessories is RC3 4 It is used to prevent water from flowing backwards After water system piping work turn on the cold water inlet valve and hot water outlet valve and star...

Страница 12: ...arge amount 1 84kg there are no additional minimum floor area requirements In case of total refrigerant amount 1 84 kg the unit should be installed operated and stored in a room with a floor area larg...

Страница 13: ...Cord mm2 Manual Switch A Capcity Fuse A Model Name Power Supply Min Diameter of Power Supply Cord mm2 220 240V 50Hz KTHR 190 1 5 For water tank with electric heating 1 5 For water tank with electric...

Страница 14: ...e properly installed with a discharge pipe run to an adequate drain and sheltered from freezing All piping properly installed and free of leaks Unit completely filled with water Water temperature limi...

Страница 15: ...ficient inlet water pressure between0 15MPa and 0 65MPa 4 2 1 Checking list before commisionning Emptying Drainpipe shut off valve Close After emptying please replace the nut of drainpipe Close Open D...

Страница 16: ...the switch is closed the unit will be stopped forcibly If switch breaks the unit can run normally according settings No Hour low bit Min high bit Min Low bit unit Explenation 12 13 14 8 9 10 11 7 TP...

Страница 17: ...lock Whenever there is any setting for clock There are daily or weekly TIMER icon If anyone of them has been set this icon will lighten the corresponding one when screen is unlocked If there is none o...

Страница 18: ...as been running for a long time without reaching the set Temp 10 11 12 Error It will be lightened when unit is under protection error VACATION MODE For the outgoing vacation mode the water tank is set...

Страница 19: ...s the TIMER button to the day timer icon press the confirmation button to enter the day timer setting interface the day timer has a total of 6 time periods each time period can be set to open the time...

Страница 20: ...tion of the up down button or pressing the return button or the power on off button you can directly exit the date and time setting 3 Setting can be done in both power on and power off state Child loc...

Страница 21: ...es 3 The 2 4GHz preferable or 5GHz band wireless signal is enabled on your wireless router Android Phone users scan Android QR code or go to google play search Nethome Plus App and download it IOS use...

Страница 22: ...US SK106 EU SK106 FCC ID 2ADQOMDNA22 IC 12575A MDNA22 US SK109 EU SK109 EU SK110 US SK110 FCC ID 2ADQOMDNA23 IC 12575A MDNA23 In Canada CAN ICES 3 B NMB 3 B Le pr sent appareil est conforme aux CNR I...

Страница 23: ...eration on panel for 1 min unit will lock the panel shows to unlock the panel please press the button for 2 seconds Q Why sometimes there is some water flowed from drainage pipe of PTR valve A Because...

Страница 24: ...nnot be started within 3 minutes of stopping The water heater cannot run for about 3 minutes after running stops when the power switch is turned on The water temperature is displayed as dropping Low a...

Страница 25: ...nk setting operation mode the tank energy saving mode host heating hot water to the maximum water temperature will stop working using electric heating heating check whether the electric heating is wor...

Страница 26: ...flow out Get off the anode rod Replace with a new one and make sure effective sealed Open cold water inlet tap untill water flows out from outlet tap then turn of water outlet tap Power on then resta...

Страница 27: ...in water tank and the pipeline and close all the valves Check the inner components regularly 7 2 Recommended regular maintenance table 7 1 Maintenance 8 Turn off the power and turn off the water inlet...

Страница 28: ......