Installation
Page 41
4. Outdoor unit installation(Side
Discharge Unit)
4.1 Service space for outdoor unit
4.2 Bolt pitch
Capacity(kBtu/h)
A(mm)
B(mm)
D(mm)
12
452
286
303
18
511
317
330
4.3 Install Outdoor Unit
Fix the outdoor unit with anchor bolts(M10)
Caution
Since the gravity center of the unit is not at its physical
center, so please be careful when lifting it with a sling.
Never hold the inlet of the outdoor unit to prevent it from
deforming.
Do not touch the fan with hands or other objects.
Do not lean it more than 45, and do not lay it sidelong.
Make concrete foundation according to the specifications
of the outdoor units.
Fasten the feet of this unit with bolts firmly to prevent it
from collapsing in case of earthquake or strong wind.