PRODIGY Technical Manual
41
8.4.11Self clean(optional)
For heat pump models which are provided with this function, after running in cooling or drying mode, if
the user press “Self Clean” button on remote controller, firstly, indoor unit runs in fan only mode for a
while, then low heat operation and finally runs in fan only again. This function can keep the inside of
indoor unit dry and prevent breeding of mold.
8.4.12 Follow me(optional)
1) If the indoor PCB receives the signal which
results from pressing the FOLLOW ME button on remote controller, the buzzer will emit a sound and
this indicates the follow me function is initiated. But when the indoor PCB receives signal which sent
from remote controller every 3 minutes, the buzzer will not respond. When the unit is running with
follow me function, the PCB will control the unit according to the temperature from follow me signal,
and the temperature collection function of room temperature sensor will be shielded, but the error
detective function of room temperature sensor will be still valid.
2) When the follow me function is available,
the PCB will control the unit according to the room temperature from the remote controller and the
setting temperature.
3) The PCB will take action to the mode
change information from remote controller signal, but it will not affected by the setting temperature.
4) When the unit is running with follow me
function, if the PCB doesn‟t receive any signal from remote controller for 7 minutes or pressing
FOLLOW ME button again, the follow me function will be turned off automatically, and the temperature
will control the unit according to the room temperature detected from its own room temperature sensor
and setting temperature.
8.4.13 Silence operation(optional)
Press the “silence” button on remote controller to initiate SILENCE function. When the Silence function
is activated, the compressor running frequency will keep lower than F2 and the indoor unit will bring
faint breeze, which will reduce the noise to the lowest level and create a quiet and comfortable room
for you.
8.4.14 Easy control(optional)
For AE series
,
On-off port, XYE port, WIFI
,
wired controller(5-cored) can be chosen at the same time.
Non-polar wired controller,4-cored wired controller, and central controller are mutually exclusive.
8.4.15 Point check function
Press the LED DISPLAY or LED or MUTE button of the remote controller three times, and then press
the AIR DIRECTION or SWING button three times in ten seconds, the buzzer will keep ring for two
seconds. The air conditioner will enter into the information enquiry status. You can press the LED
DISPLAY or AIR DIRECTION button to check the next or front item‟s information within 27 seconds.
Содержание KAE-26 DN7
Страница 1: ...PRODIGY 3D Inverter Technical Manual ...
Страница 11: ...PRODIGY Technical Manual 11 For KAY 26 DN7 ...
Страница 12: ...PRODIGY Technical Manual 12 For KAY 35 DN7 For KAY 52 DN7 ...
Страница 13: ...PRODIGY Technical Manual 13 For KAY 71 DN7 ...
Страница 14: ...PRODIGY Technical Manual 14 3 2 Outdoor Unit ...
Страница 15: ...PRODIGY Technical Manual 15 For KAE 26 DN7 ...
Страница 16: ...PRODIGY Technical Manual 16 For KAE 35 DN7 KAE 52 DN7 ...
Страница 17: ...PRODIGY Technical Manual 17 For KAE 71 DN7 ...
Страница 64: ......