RCM Software Installation & Use
2. Start RCMS
Start RCMS. RCMS must be run as Administrator; hold
the Shift key then right-click on the RCMS icon and select
Run as Administrator from the pop-up context menu.
3. Connect RCMS to the CLASSIC
After RCMS has started, you must specify the Unit number of the CLASSIC device (also called the Modbus Node
Address) and the COM port used by the RS-485 Adapter.
RCMS will connect immediately if the previous settings used are still valid.
The default Unit number is Unit 1, which is the
CLASSIC factory default Node Address.
The COM port the CLASSIC is connected to can
be found through Windows Device Manager. In the
following figure, Device Manager shows a single USB
Serial Port which has been assigned COM8.
After setting the Unit number and COM port, click the
Refresh icon to connect to the CLASSIC.
If the connection is successful, RCMS will remember
the COM port and Unit number and use them the next
time it is run.
2
3
Click to Attempt Connection