CLASSIC
®
800 Product Manual
v
kayden.com Online Store
CLASSIC
®
800 Technical Specifications
Thermal Dispersion
CLASSIC
®
800 Technical Specifications
kayden.com Online Store
Applications
•
Flow, Level, Interface & Temperature
Process Connections
•
1/2”, 3/4”, 1”, 1-1/4”, 1-1/2” & 2” MNPT
•
3/4” FNPT & Flanged InLine
•
Threaded (1” MNPT) & Flanged
Retractable Packing Glands
Insertion ‘U’ Lengths
•
Imperial
1.2”, 2”, 3”, 4”, 6”, 9”, 12” & 18” standard
•
Metric
3, 5, 7.5, 10,15, 23, 30 & 45 cm standard
•
Custom Lengths
Available in 1/2” or 1 cm increments
Min. 2.5” - Max. 120” (6.0 - 305 cm) model
dependant
Wetted Materials
•
316/316L Stainless Steel - standard
•
Titanium Gr. 2, Hastelloy C-276
•
316/316L Stainless Steel c/w Nickel Braze
(830 & 832 InLine Models)
•
Highly Saturated Nitrile
(Pressure Seal - 814 & 816 Packing
Gland Models)
Enclosure Material
•
Copper-free Aluminum
(does not exceed 0.4% copper)
•
Powder Coated Polyester TGIC
(polyester triglycidyl isocyanurate)
•
NEMA 4, 4X, 6P; IP65/67
•
1” FNPT Conduit Connection
•
Buna O-Ring on Cover
Temperature Range – Continuous Service
•
Sensors
-55°C to +200°C (-58°F to +392°F)
(Models 814 & 816: -55°C to +160°C [-58°F to
+320°F])
•
Electronics
-55°C to +65°C (-67°F to +149°F)
Note:
For temperatures above +65°C (+149°F)
electronics must be remotely mounted. Refer to
Electronics Location Considerations Page 10.
•
Storage
Product should be stored in a clean and dry
environment between -30° and +60° C (-34.5°
and 140° F)
Operating Pressure - Sensor
Threaded Style
•
Maximum Working Pressure
24 MPa (3500 psig) dependent on
model and material of construction
Flanged Style
•
Maximum Working Pressure
per flange rating
Switch / Transmitter Switch Point Range
(Insertion Style - 1/2” to 2”MNPT, Flanged)
•
Water-based Liquids
0.01 to 3.0 ft./sec. (0.003 to 0.9 meters/sec.)
•
Hydrocarbon-based Liquids
0.01 to 5.0 ft./sec. (0.003 to 1.5 meters/sec.)
•
Gases
0.25 to 254 sfps (0.076 to 77 smps)
Standard conditions: 21°C (70°F) at 14.7 psi (1 atm)
Switch / Transmitter Switch Point Range
(InLine Style)
•
Water-based Liquids
0.015 to 50 cc/sec.
•
Hydrocarbon-based Liquids
0.033 to 110 cc/sec.
•
Gases
0.6 to 20,000 cc/sec.
Standard conditions: 21°C (70°F) at 14.7 psi (1 atm)
Accuracy
•
Flow Service
±1% set point velocity over operating range of
±28°C (±50°F)
•
Level Service
±0.25 inches (±0.64 cm)
•
Repeatability
±0.5% Thermal Signal
•
Hysteresis (Dead Band)
±1% Thermal Signal
•
Temperature
±1° C or ±2% of full-scale range, whichever is
greater.
CLASSIC
®
800 Specifications