Instructions for use Primus 1058 Life
10 Data on electromagnetic compatibility according to EN 60601-1-2 | 10.4 Immunity to electromagnetic interfer-
ence
Rated power P of the
transmitter in W
Safe distance depending on the transmission frequency in m
150 kHz to 80 MHz
d=1.17
P
80 MHz to 800 MHz
d=1.20
P
800 MHz to 2.5 GHz
d=2.3
P
0.01
0.12
0.12
0.23
0.1
0.37
0.38
0.73
1
1.17
1.20
2.3
10
3.69
3.79
7.27
100
11.7
12
23
U1 = Compliance level according to 4-6: 3 V
eff
E1 = Compliance level according to 4-3: 3 V/m
Factor
[3.5/U1]
[12/E
1
]
[23/E
1
]
For transmitters whose maximum rated power is not included in the above
table, the recommended safe distance d in metres (m) can be calculated using
the equation for the respective column, where P is the maximum rated power
of the transmitter in Watts (W) as specified by the manufacturer.
NOTE: At 80 MHz and 800 MHz, the higher frequency range applies.
ANMERKUNG 2 Diese Leitlinien mögen nicht in allen Fällen anwendbar sein. The
spread of electromagnetic waves is absorbed and reflected by buildings, objects
and people.
10.4 Immunity to electromagnetic interference
The treatment unitPrimus 1058 Life is designed for operation in an environment
as specified below. The customer or user of the Primus 1058 Life should make
sure that the device is used in an environment of the specified type.