Special Functions
80 of 100
20.1.6
Attenuation Test
During the attenuation test, the level measurement is carried out in one place. This level
is defined as a reference level. After this, the meter is calibrated so that all the settings
are set to 0. When the level measurement is carried out in a different location, the meter
shows the level deviation between the two measurement points.
20.1.7
SAT Point
This function is a special view of the spectrum analyser, during which the max hold func-
tion is activated by default and the RF measurement range end value is set to 90 dB.
Using this function, it is possible to monitor the field strength by visualising the signal
envelope and following the maximum achieved values in order to be able to align the sat-
ellite antenna in the direction of the maximum signal strength.