zinc anode in all installations (at least every two to 
three months).

Seal replacement and all other repair services should 
be performed by Kasco Marine or a Kasco trained 
Authorized Repair Center.  Please contact your Kasco 
Marine, Inc. distributor or representative for your 
nearest Authorized Repair Center.

UNIT STORAGE: When storing units during the 
offseason, it is important to store them upside down 
if they are going to be sitting for long periods of time.  
Units that sit upright on a shelf for many months, or 
even years have a greater likelihood of seals drying 
out.  Storing upside down will ensure oil is lubricating 
the seals and prevent drying.  

Troubleshooting Tips

Below are some helpful troubleshooting tips.  If a 
problem occurs, please double check the assembly and 
installation instructions as well as the instructions for 
the proper control panel.  More troubleshooting tips 
can be found at www.de-icer.com. (Under the Helpful 
Info tab)

“ My De-Icer trips a ground fault interrupter.”

 

This is the most common symptom of several 

possible problems.  To correctly diagnose the problem,  
you will need to collect more information.  A Ground 
Fault Interrupter (GFI) that trips can indicate an elec-
trical service problem, water contamination in the unit 
and/or cord, bad breaker, control box problems, motor 
problems, etc.  Try to fi nd out the answers to these 
questions before you contact Kasco to narrow down 
the problem.  

How long does it take to trip the breaker?  

• 

Does it always take the same amount of time to trip?

• 

How many times has it tripped?

• 

Has there been any electrical problems in the area 

• 

recently?

“My De-Icer seems to run slowly.”

 

This can also be a symptom of several possible 

problems.  There could be an electrical problem where 
the unit is not getting the proper voltage.  This could 
also indicate a problem with the motor of the unit, 
which needs to be looked at by an Authorized Repair 
Center.  Check that the unit is receiving the proper 
voltage, and, if so, contact Kasco for further steps.

Note:  If the De-Icer has been stored or exposed to 

distributor or representative for further instructions.

If the supply cord becomes damaged, it must be 
replaced by an authorized service center, or similarly 
qualifi ed persons in order to avoid a hazard.

OBSERVATION:  Operating equipment should be 
observed on a regular basis (daily, if possible) for any 
reduction or variation in performance.  If a change 
in performance is observed, the equipment should 
be disconnected from power and inspected for any 
material that may have clogged the system or wrapped 
around the shaft of the motor, especially plastic bags 
and fi shing line.  Even though Kasco De-Icers are 
among the most clog-resistant on the market, it is 
impossible to protect against all items that can clog 
equipment and still maintain a fl ow of water.  These 
materials can be very damaging to the equipment 
under continued operation and must be removed as 
soon as possible.  ALWAYS DISCONNECT POWER 
TO THE UNIT BEFORE ATTEMPTING TO 
REMOVE CLOGS.

CLEANING:  Equipment should be removed from the 
water at least once per year to clean the exterior of the 
system, especially the stainless steel motor housing 
(can).  The motor housing is the surface that dissipates 
heat into the water and any algae, calcium, etc. build-
up will become an insulator that blocks heat transfer.  
In warmer regions it is recommended that the motor 
is removed and cleaned at least two to three times per 
year depending on conditions.  In most cases a power 
washer will be suffi cient if the unit and algae are still 
wet.

SEAL AND OIL REPLACEMENT:  This is a sealed 
motor assembly and seals will wear out over time 
(similar to brake pads on a car).  Replacement of the 
seals and a change of oil after three years may add 
longevity to the operation of the motor, saving you the 
cost of more expensive repairs.  

ZINC ANODE:  A Sacrifi cial Zinc Anode is supplied 
on the shaft of all Kasco De-Icers for protection of 
the equipment from corrosion and electrolysis.  The 
zinc anode should be replaced if reduced to half 
the original size or if white in color.  Corrosion 
from electrolysis is more commonly associated 
with saltwater or brackish water, but as a matter of 
precaution, it is important to periodically check the 

Содержание De-Icer 3400ED

Страница 1: ...ns 6 Troubleshooting Tips 7 Replacement Parts Diagram 9 Additional Accessories for Your De Icer 10 Customer Repair Form 11 Registration Information 12 Rev 05 22 12 Kasco Marine Inc 800 Deere Rd Presco...

Страница 2: ...ation Note Under certain conditions no de icer can prevent damage from ice movement caused by wind or current or from extremely cold weather Unit Specs Model Voltage Operating amps lock rotor amps 240...

Страница 3: ...eed bolts screws nails or brackets unless an op tional mounting device was purchased All you have to do is suspend it in as little as two 2 feet of water from piers docks or boats and plug it into a p...

Страница 4: ...ck piling cleat boat etc so the De Icer hangs vertically Ice Expansion Pressure Open water buffer releases ice expansion pressure Kasco Horizontal Flotation units Shore Shore Ice collars Uneven liftin...

Страница 5: ...remove the knot and splice of the rope simply change the point at which the line leaves the propeller cage by looping the rope around the top circular band over 1 to 4 vertical cage wires more than 4...

Страница 6: ...eplacement with new Please ship according to the instructions in the previous section Again it is best to call ahead for updated information and or Repair Form Kasco Marine does estimates on repairs a...

Страница 7: ...Icer has been stored or exposed to distributor or representative for further instructions If the supply cord becomes damaged it must be replaced by an authorized service center or similarly qualified...

Страница 8: ...ping the GFI breaker Each Kasco unit has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down it will start back up If you are noticing these symptom...

Страница 9: ...NG ORING 1 4A 243475 ZINC ASSEMBLY 2400 3400 MODELS 1 4B 840475 ZINC ASSEMBLY 4400 8400 MODELS 1 5A 240170 2400 K PROP 2400 MODEL 1 5B 340125 3400 J PROP 3400 MODEL 1 5C 440400 4400 M PROP 4400 MODEL...

Страница 10: ...water and is well suited for shallow water operation Visit www de icer com for more information on these accessories for your de icer Additional Accessories for Your De Icer C 10 Thermostat Control T...

Страница 11: ...t include the power cord and cage assembly with each unit sent in for repair to be considered for warranty and for proper repair and shipping protection Do not ship the float and or control box with t...

Страница 12: ..._________________________ Serial Ex 8001D341725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ________________...

Отзывы: