manualshive.com logo in svg
background image

9

1

2

4

5

6

7

8

9

3

ITEM NO.

PART NO.

DESCRIPTION

QTY.

1A

990275

CORD O RING

1

2

990280

SEALING PLUG

1

3

990281

SEALING ORING

1

4A

243475

ZINC ASSEMBLY (2400 & 3400 MODELS)

1

4B

840475

ZINC ASSEMBLY (4400 & 8400 MODELS)

1

5A

240170

2400 K PROP (2400 MODEL)

1

5B

340125

3400 J PROP (3400 MODEL)

1

5C

440400

4400 M PROP (4400 MODEL)

1

6

261234

HEX NUT

1

7

261240

5/16-18 X 1 HHCS

1

8

990201

CAGE

1

9

261231

FLAT WASHER

2

Replacement Parts Diagram

Содержание De-Icer 3400ED

Страница 1: ...ns 6 Troubleshooting Tips 7 Replacement Parts Diagram 9 Additional Accessories for Your De Icer 10 Customer Repair Form 11 Registration Information 12 Rev 05 22 12 Kasco Marine Inc 800 Deere Rd Presco...

Страница 2: ...ation Note Under certain conditions no de icer can prevent damage from ice movement caused by wind or current or from extremely cold weather Unit Specs Model Voltage Operating amps lock rotor amps 240...

Страница 3: ...eed bolts screws nails or brackets unless an op tional mounting device was purchased All you have to do is suspend it in as little as two 2 feet of water from piers docks or boats and plug it into a p...

Страница 4: ...ck piling cleat boat etc so the De Icer hangs vertically Ice Expansion Pressure Open water buffer releases ice expansion pressure Kasco Horizontal Flotation units Shore Shore Ice collars Uneven liftin...

Страница 5: ...remove the knot and splice of the rope simply change the point at which the line leaves the propeller cage by looping the rope around the top circular band over 1 to 4 vertical cage wires more than 4...

Страница 6: ...eplacement with new Please ship according to the instructions in the previous section Again it is best to call ahead for updated information and or Repair Form Kasco Marine does estimates on repairs a...

Страница 7: ...Icer has been stored or exposed to distributor or representative for further instructions If the supply cord becomes damaged it must be replaced by an authorized service center or similarly qualified...

Страница 8: ...ping the GFI breaker Each Kasco unit has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down it will start back up If you are noticing these symptom...

Страница 9: ...NG ORING 1 4A 243475 ZINC ASSEMBLY 2400 3400 MODELS 1 4B 840475 ZINC ASSEMBLY 4400 8400 MODELS 1 5A 240170 2400 K PROP 2400 MODEL 1 5B 340125 3400 J PROP 3400 MODEL 1 5C 440400 4400 M PROP 4400 MODEL...

Страница 10: ...water and is well suited for shallow water operation Visit www de icer com for more information on these accessories for your de icer Additional Accessories for Your De Icer C 10 Thermostat Control T...

Страница 11: ...t include the power cord and cage assembly with each unit sent in for repair to be considered for warranty and for proper repair and shipping protection Do not ship the float and or control box with t...

Страница 12: ..._________________________ Serial Ex 8001D341725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ________________...

Отзывы: